S G M 1 4 0 0 S e r i e s S m a r t M e t e r U s e r M a n u a l – S M E T S 2
57
Chapter 6 • Advanced Features
Days
Up to five days can be individually configured to have non-disablement and
disablement periods. One is specifically used to define a profile for special days
(non-disablement all day), and the other four are used for the week profiles. Only
two days which are configured to have non-disablement/disablement periods may
be used each week.
Weeks
Two week profiles are available, and each of these can be configured using two
day profiles.
Seasons
Three seasons can be configured as specified by date ranges, where each season
can have two week profiles.
Special Days - Holidays
As well as the periods defined in the previous section, whole days can be specified
as friendly credit holidays – special days. Up to 20 individual dates can be
specified (e.g., Xmas Day and Boxing Day).
Special days override any period configuration specified by the days within the
week.
Disconnector Control Mode
For the prepayment function to operate the disconnect switch effectively, the
Disconnector Control mode is defaulted to Mode 200.
This allows for internal disconnection (in the event of credit exhaustion) and
re-arming where sufficient credit has been added to the meter to allow
re-connection. The illustration below depicts Mode 200 state transitions.
Summary of Contents for SGM1400 Series
Page 2: ......
Page 4: ...ii S G M 1 4 0 0 S e r i e s S m a r t M e t e r U s e r M a n u a l S M E T S 2...
Page 12: ...2 S G M 1 4 0 0 S e r i e s S m a r t M e t e r U s e r M a n u a l S M E T S 2 Aclara Support...
Page 54: ...44 S G M 1 4 0 0 S e r i e s S m a r t M e t e r U s e r M a n u a l S M E T S 2 Billing Data...
Page 94: ...84 S G M 1 4 0 0 S e r i e s S m a r t M e t e r U s e r M a n u a l S M E T S 2 Disposal...