ACL 2000 FLAME FAIL IGNITION SYSTEM

WARNING

ACL is not responsible for the misuse or incorrect application of this product.

This manual must be read in its entirety before installation of this system.

Installation must be performed by a qualified technician and must adhere to the 

standards set by the local regulatory authorities.

ACL 2000

FLAME FAIL

IGNITION MANUAL

Summary of Contents for 2000

Page 1: ...2000 FLAME FAIL IGNITION SYSTEM WARNING ACL is not responsible for the misuse or incorrect application of this product This manual must be read in its entirety before installation of this system Installation must be performed by a qualified technician and must adhere to the standards set by the local regulatory authorities ACL 2000 FLAME FAIL IGNITION MANUAL ...

Page 2: ...4 6 Manufacturing Inc ACL ACL 2000 FLAME FAIL IGNITION SYSTEM ...

Page 3: ...m control capabilities Application The ACL 2000 Flame Fail Ignition System provides safe and reliable ignition flame recognition for all types of gas fired heating appliances including line heaters reboilers dehydrators and treaters Economically priced and easy to install the ACL 2000 mounts into position through a 1 NPT collar eliminating unnecessary welding and installation of expensive latching...

Page 4: ...per positioning schedule 40 piping is recommended Pilot nozzle tip must not extend past the burner into the main flame A clean steady dry fuel gas supply 25 PSI max is required for reliable operation When only wet gas is available it is recommended that a coalescing filter be installed before the gas leaves the heated building or directly after the filter regulator Purge air and debris from lines ...

Page 5: ...IGNITION SYSTEM ACL 2000 and ACL High Efficiency Burner installed on boil off tank ACL2000 Main Burner Temp Control Valve Safety Shutdown Valve Main Burner Regulator Supply Pilot Regulator Supply 20 25 psi Supply Output Manual Shut Off Valve Optional Low level Shutdown ...

Page 6: ...10 15 20 25 30 Replacing Pilot Ignitor Tube 12 1 Remove cap screws 8 loosen housing set screw 10 and slide aluminum housing 1 Down the pilot ignitor tube 12 2 Disconnect lead wire from piezo button 4 and disconnect thermocouple from gas valve button 2 3 Disconnect the pilot line from pilot valve assembly 3 4 Slide pilot ignitor tube 12 through the aluminum housing 1 and replace with new pilot igni...

Page 7: ..._____________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ __________________________________________________________...

Page 8: ...product which is found to be defective in such workmanship or material will be repaired or replaced by Seller for a period of one year from purchase date Warranty of such items do not include shipping installation or set up Liability Statement ACL Manufacturing Inc Shall not be liable for any special indirect consequential or other damages of a like general nature including without limitation loss...