598-1231-00

3. Testing

1.  Remove the existing fixture.

2.  After screwing the sensor into the wall plate, connect the junc-

tion box wires to the light control wires as shown in Figure 1:

• Black 

sensor wire to the 

black 

(HOT) house wire.

• 

White 

sensor wire to all 

white 

(NEUTRAL) house and lamp 

wires.

• 

Red

 (SWITCHED HOT) sensor wire to 

black

 lamp wires.

3.  Mount light fixture according to the instructions that came with 

your fixture.

2. Aiming

Figure 2 - Coverage Angles

240°

8 Ft.

100 Ft.

Figure 1 - Wiring Sensor Head

D

UAL

B

RITE

®

Replacement

Sensor Head

Specifications:

Total Lighting Wattage .. Up to 500 Watts Maximum Incandescent

Range .........................up to 70 ft.; up to 100 ft. with Range Boost

Time Delay ........................................................1, 5, or 20 minutes

D

UAL

B

RITE

®

 ....................................Off, 3, 6 hours, Dusk-to-Dawn

CAUTION: This product is to be used with a U.L. listed rain 
tight or wet location suitable outlet box. Depending on the 
installation, additional hardware may be required.

Note:

 Installation of this light control should be done only by 

those with experience in 120 Volt household wiring. Install in 

accordance with local codes. Some local codes may require that 

a licensed electrician install the light control.

Models 3009701 / 3209996

1. Installation

CAUTION: Always turn the circuit breaker off when wir-
ing the fixture.

For motion sensing,

 put the ON-TIME switch on the bottom of 

the sensor in the 1, 5, or 20 minute position. When motion is detected, 

the lights will come on the selected time. 

Note:

 

The photocell keeps 

the lights from turning on in daylight.

To keep lights on all night,

 flip the light switch off for 1 second 

then back on. To return the sensor to the motion sensing mode, flip 

the light switch off for 1 second then back on. At dawn, the control 

will return to the motion sensing mode and shut off.

For  accent  lighting,

 set the D

UAL

B

RITE

®

 switch to the 3, 6, or 

Dusk-to-Dawn setting. The lights will turn on dim at sundown for 

the set time. When motion is sensed the lights will turn on full bright 

for the set ON-TIME period. The lights will return to dim during the 

set D

UAL

B

RITE

®

 period.

4. Operation

Turn  the  power  back  on  at  the  circuit  breaker.  Turn  the  light 

switch on.

Note:

 When first turned on wait about 1 

1

/

2

 minutes for the circuitry 

to calibrate.
Put the ON-TIME switch on the bottom of the sensor in the TEST 

position. You can now walk in front of the unit and the lights will come 

on for about 5 seconds. The TEST mode works both day and night.
Walk through the coverage area and point the sensor to obtain the 

desired coverage area. Adjust sensitivity as needed. Use RANGE 

BOOST only if required.

The coverage area for the sensor is shown in Figure 2. The sensor 

should be aimed so that the motion to be detected is in front of and 

across the coverage area. The sensor should be aimed looking out 

at a horizontal angle. To reduce false triggering, point the sensor 

away from traffic areas, air conditioners, dryer vents, water pools, 

or anything which may move or change temperature rapidly.

This  light  control  automatically  turns  on  lights  when  motion  is 

detected. On-time is selectable from Off, 1, 5, or 20 minutes. A 

photocell keeps the lights off during the day. Patented D

UAL

B

RITE

®

 

timer provides accent lighting.

CAUTION: Do not mount the sensor above or touching 
the lamps. Keep regular PAR-38 lamps at least 1" (25 mm) 
from the sensor. Halogen lamps should be kept at least 
2" (51 mm) from the sensor. The sensor bottom must be 
facing down for best coverage and to avoid water damage 
and electrical shock.

Note:

 

For under-eave installation, rotate the sensor head 180° by 

bending the sensor towards the clamp bracket. Rotate the sensor 

bottom clockwise away from the bracket.

 

BLACK

 Sensor Wire and 

BLACK

 Junction Box Wire

 

All 

WHITE

 Wires

 

RED

 Sensor Wire and 

BLACK

 Lamp Wires

Optional:

 Connect additional load across the white and 

red sensor wires. Total lighting load including lamp-

heads on fixture(s) must not exceed 500W (4.2A).

Junction Box

Lamp 

Holders