Chapter
4 Configuration
Installation and Operation Manual
4-110 Configuring for Operation
ACE-3105, ACE-3205 Ver. 5.2
Parameter Description
Possible
Values
•
The peer number cannot be changed
dynamicaly (on-the-fly).
Provisioning
mode
Determines whether the PW is established
manually or by LDP signaling
Manual
LDP PW ID
Default: Manual
PW ID
A unique ID number that must be defined
identically on both the local and remote unit.
This ID is used to identify the PW connection
when labels are exchanged with LDP.
1–4294967295
Out PW label
The PW label that is used in the outbound
direction. Relevant only if the provisioning mode
(see above) is set to Manual.
The out label's value range depends on the
selected PSN type.
1–4095 if the PSN type
is UDPoIP
16–1048575 for any
other PSN type
In PW label
The PW label that is used in the inbound
direction. Not relevant for clock distribution.
If the PW is defined manually and the PSN type is
MPLS, MPLSoIP or MPLSoGRE, the PW value range
must be within the static label range.
1–4095 if the PSN type
is UDPoIP
16–65534 for any other
PSN type
Control word
Determines whether a control word is used
on this PW.
The control word can be disabled only in the
following PW types (see above):
•
ATM VP 1 to 1
•
ATM VC 1 to 1
•
ATM VP N to 1
•
ATM VC N to 1.
For detailed information about the control word
structure, refer to
Appendix E
.
Enable
Disable
Default: Enable
Sequence
number
When disabled, the Sequence bit in the control
word equals zero (0). Relevant only if the control
word is enabled (see above).
Sequence numbering can be disabled only in the
following PW types:
•
ATM VP 1 to 1
•
ATM VC 1 to 1
•
ATM VP N to 1
•
ATM VC N to 1.
In addition, the AAL5-SDU PW type does not
support sequence numbering (set to Disable).
Enable
Disable
Default: Enable