![Ace ACE-3105 Installation And Operation Manual Download Page 283](http://html1.mh-extra.com/html/ace/ace-3105/ace-3105_installation-and-operation-manual_457309283.webp)
Installation and Operation Manual
Chapter
6 Monitoring and Diagnostics
ACE-3105, ACE-3205 Ver. 5.2
Monitoring Performance
6-45
Table
6-32. CES User Statistics Parameters
Parameter Description
Possible
Values
Sequence errors
Number of times that the sequence number of
an incoming AAL1 SAR-PDU cell causes a
transition from the Sync state to the Out of Sync
state, according to the Fast-SN algorithm
(according to ITU I.361.1 Section III.2.4.2)
Numerical
CES header errors
Number of AAL1 header errors, including
corrected ones. Cells with a header error are cells
that have an erroneous Sequence Number Parity
(SNP) value.
Numerical
Buffer underflow
Number of times the CDVT buffer was in
underflow state
Numerical
Buffer overflow
Number of times the CDVT buffer was in overflow
state
Numerical
Pointer mismatch
Number of times a pointer mismatch was found
Numerical
RX cells
Number of cells received on the ATM channel
Numerical
TX cells
Number of cells transmitted on the ATM channel
Numerical
Discarded cells
Number of cells discarded from the ATM channel
Numerical
Time Elapsed /
Start Time
Time Elapsed is the period in seconds since the
beginning of the current interval.
Start Time is for intervals 1–24.
0–899
Valid intervals
The number of intervals that are saved
0–24
Interval number
The interval number to be displayed
0–last interval, max 24
0 if no interval
Default: 0
XC ID
ID of the XC for which the statistics above are
displayed
XC number
³
To view the CES XC OAM user statistics:
•
From the CES XC monitoring menu, select OAM Statistics.
explains the displayed user statistics parameters and other
display options that are available.