before you have the capillary tube and thermobulb in its final position.  

Once thermobulb and capillary are 

in their final position, you are ready to secure the thermobulb and capillary tube in place.   

13  Coat the outer threads only of the 3/8” hex pipe plug (the large plug) with Teflon pipe sealant.  Thread this hex 

pipe plug into the weld coupling securely.  

14  Slide the brass ferrule into the recessed center of the 3/8” hex pipe plug (brass ferrule is located on the capillary 

tube in between the large and small hex pipe plugs). 

15  Once the brass ferrule is in place, engage the threads of the small hex pipe plug into the internal threads of the 

3/8” hex pipe plug until it stops.  

Caution:  Do not loosen this connection after it has been tightened down, 

doing so will cause kettle jacket to leak. 

 

Caution:  Do not use Teflon sealant on this connection.

 

16 Replace access panel and secure in place.   

17 Refill kettle with pure distilled water. 

Heating Element Replacement 

To replace a heating element, disconnect the leads of the defective element at contactor.  Unscrew the defective 

element from its coupling.  Install new element in coupling and reconnect wires to the contactor.   

Make sure all covers are replaced after all repairs are completed.

 

Trouble Shooting 

The 

TT-TT2/3J-T-E20QT  and  TT-TT2/3J-T-E40QT 

kettles  are  designed  to  operate  smoothly  and  efficiently  if 

properly  maintained.    However,  the  following  is  a  list  of  checks  to  make  in  the  event  of  a  problem.    Wiring 

diagrams are furnished in this manual.  If an item on ths list is followed by an asterisk (*), the work should be done 

by a qualified service or maintenance person. 

Symptoms 

What to check for

 

Kettle will not heat, pilot light will not come on 

That the power supply is on 

For loose or broken wires 

Thermostat functioning properly* 

Contactor functioning properly* 

Automatic low water relay engaged, amber light should 

be on if this has happened 

Kettle continues to heat after it reaches desired 

temperature 

Thermostat setting.  Turn it down if too high 

Thermostat functioning properly* 

Contactor, to determine if it is de-energized* 

Kettle does not reach desired temperature 

Thermostat setting.  Turn it up if too low. 

Thermostat functioning properly* 

Check for air in kettle jacket, refer to Kettle Venting 

Instructions 

Heating elements for ground short or open (burned out) 

element.* 

Thermostat functioning properly* 

Contactor functioning properly* 

6

Summary of Contents for EDGE ALTEH-5

Page 1: ...Made in U S A INSULATED SELF CONTAINED TILTING TABLE TOP ELECTRIC OWNERS MANUAL AND INSTALLATION INSTRUCTIONS Models ALTEH 5 and ALTEH 10 MODEL ALTEH 10...

Page 2: ...Calibrating Thermostats 5 Primary Thermostat Replacement 5 Heating Element Replacment 6 Trouble Shooting 6 Illustrations 7 Caring for Stainless 8 Sanitizing 8 Parts List 10 Wiring Diagrams 11 11 12 20...

Page 3: ...for safe delivery to the customer until customer acceptance of the package Careful inspection of the packaging and the appliance should be completed before acceptance from the transportation company...

Page 4: ...n the main and the kettle All electrical connections must be in accordance with all applicable electrical codes The electrical wiring diagram is located inside the control housing Caution Kettle must...

Page 5: ...is particularly true if the unit is cold Keeping the cover closed during this heat up time will speed up the process If a new temperature is desired during the cooking operation turn the control therm...

Page 6: ...E Caution Be sure the main power supply switch is OFF before cleaning and or servicing Caution Use of any replacement parts other than those supplied or authorized by manufacturer voids all warranties...

Page 7: ...ected to the normally closed position with the enclosed tag marked normally closed 3 Disconnect and mark wire s connected to the common position with the enclosed tags marked common 4 Drain water in j...

Page 8: ...ng Install new element in coupling and reconnect wires to the contactor Make sure all covers are replaced after all repairs are completed Trouble Shooting The TT TT2 3J T E20QT and TT TT2 3J T E40QT k...

Page 9: ...to see if it is too low Contactor for dirt or corrosion on the contacts Uneven cooking due to cold spots For burned out open or loose heating elements See Service section for test and replacement pro...

Page 10: ...agents thoroughly with water wipe dry and then allow the surface to air dry Oxygen actually helps maintain stainless steel s protective surface Never use cleaners containing chlorides or quaternary s...

Page 11: ...valent to one that supplies 200 parts per million available chlorine Obtain advise on sanitizing agents from your supplier of sanitizing products Following the supplier s instructions apply the agent...

Page 12: ...408015 25 Contactor 25 amp 600V 2 408015 40 Contactor 40 amp 600V 2 408015 60 Contactor 60 amp 600V 2 430033 Transformer all volts 480 440 415 380 1 400749 1 Ground lug 14 to 6 2 406619 Fuse 2 amp 2...

Page 13: ...Wiring Diagrams ALTEH 5 10 GAL 208 240 3PH 11...

Page 14: ...Wiring Diagrams ALTEH 5 10 GAL 440 460 480 3PH 12...

Page 15: ...Wiring Diagrams ALTEH 5 10 GAL 380 415V 3PH 13...

Page 16: ...Maintenance Service Log Model No Purchased From Serial No Date Purchased Purchase Order No Location Installed Date Installed Date Maintenance Performed Performed By 14...

Page 17: ...rm the repair or replacement This warranty includes travel time not to exceed two hours and mileage not to exceed 50 miles 100 miles round trip but does not include post start up assistance or trainin...

Page 18: ...IMPORTANT SERVICE INFORMATION AccuTemp Product Inc Technical Customer Support Technician is available Monday thru Sunday 7 00am to 7 00pm EST...

Reviews: