Appliance failure caused by inadequate water quality is not covered under warranty. 

Caution:  Drain the steam jacket if the kettle is to be stored in an unheated area.  Water freezing in the 

steam jacket may cause damage to the unit. 

OPERATION 

D

AILY 

O

PERATION

 

Refilling the steam jacket is seldom necessary, however should the water level go below the minimum level, which 

would be indicated by the amber light located on the control console being illuminated, (Refer to Water Fill 

Instructions).

 

It is suggested that the excess air within the kettle jacket be vented after initial filling of steam jacket and start-up 

each day by lifting release lever of the safety valve (Refer to Kettle Venting Instructions Section). 

C

AUTION

:

  

C

ARE SHOULD ALWAYS BE TAKEN WHEN VENTING LIVE STEAM

To operate the kettle, set the thermostat dial to the desired cooking temperature.  Allow the unit to cycle a number 

of times before assuming the cooking surface has reached and stabilized at the desired temperature.  This is 

particularly true if the unit is cold.  Keeping the cover closed during this heat-up time will speed up the process.  If a 

new temperature is desired during the cooking operation, turn the control thermostat to the desired setting.  Again, 

allow the unit to cycle a number of times to insure proper heat stabilization. 

Place the thermostat in the "OFF" position when the kettle is not in use. 

All self-contained kettles are designed with low water cutoff protection.  This is indicated by an amber light, located 

adjacent to the thermostat knob. 

The unit is designed with automatic shut off when the kettle is tilted.  Care should be taken when tilting unit filled 

with heated product.  We recommend turning off the power when pouring. 

Kettle Venting Instructions 

0

30

100

PSI

20

40

60

80

Hg

TEMPERATURE LESS THAN 125 F

WITH AIR IN KETTLE

When the kettle temperature is at less than 125

°

F and the vacuum/pressure gauge 

reading is at or slightly below “0”,  it means that air has entered the steam/water 

jacket, resulting in little or no vacuum.  Air inside the jacket will act as an insulator 

therefore reducing kettle efficiency.  To remedy this situation, the following venting 

procedures should be followed: 

3

Summary of Contents for EDGE ALTEH-5

Page 1: ...Made in U S A INSULATED SELF CONTAINED TILTING TABLE TOP ELECTRIC OWNERS MANUAL AND INSTALLATION INSTRUCTIONS Models ALTEH 5 and ALTEH 10 MODEL ALTEH 10...

Page 2: ...Calibrating Thermostats 5 Primary Thermostat Replacement 5 Heating Element Replacment 6 Trouble Shooting 6 Illustrations 7 Caring for Stainless 8 Sanitizing 8 Parts List 10 Wiring Diagrams 11 11 12 20...

Page 3: ...for safe delivery to the customer until customer acceptance of the package Careful inspection of the packaging and the appliance should be completed before acceptance from the transportation company...

Page 4: ...n the main and the kettle All electrical connections must be in accordance with all applicable electrical codes The electrical wiring diagram is located inside the control housing Caution Kettle must...

Page 5: ...is particularly true if the unit is cold Keeping the cover closed during this heat up time will speed up the process If a new temperature is desired during the cooking operation turn the control therm...

Page 6: ...E Caution Be sure the main power supply switch is OFF before cleaning and or servicing Caution Use of any replacement parts other than those supplied or authorized by manufacturer voids all warranties...

Page 7: ...ected to the normally closed position with the enclosed tag marked normally closed 3 Disconnect and mark wire s connected to the common position with the enclosed tags marked common 4 Drain water in j...

Page 8: ...ng Install new element in coupling and reconnect wires to the contactor Make sure all covers are replaced after all repairs are completed Trouble Shooting The TT TT2 3J T E20QT and TT TT2 3J T E40QT k...

Page 9: ...to see if it is too low Contactor for dirt or corrosion on the contacts Uneven cooking due to cold spots For burned out open or loose heating elements See Service section for test and replacement pro...

Page 10: ...agents thoroughly with water wipe dry and then allow the surface to air dry Oxygen actually helps maintain stainless steel s protective surface Never use cleaners containing chlorides or quaternary s...

Page 11: ...valent to one that supplies 200 parts per million available chlorine Obtain advise on sanitizing agents from your supplier of sanitizing products Following the supplier s instructions apply the agent...

Page 12: ...408015 25 Contactor 25 amp 600V 2 408015 40 Contactor 40 amp 600V 2 408015 60 Contactor 60 amp 600V 2 430033 Transformer all volts 480 440 415 380 1 400749 1 Ground lug 14 to 6 2 406619 Fuse 2 amp 2...

Page 13: ...Wiring Diagrams ALTEH 5 10 GAL 208 240 3PH 11...

Page 14: ...Wiring Diagrams ALTEH 5 10 GAL 440 460 480 3PH 12...

Page 15: ...Wiring Diagrams ALTEH 5 10 GAL 380 415V 3PH 13...

Page 16: ...Maintenance Service Log Model No Purchased From Serial No Date Purchased Purchase Order No Location Installed Date Installed Date Maintenance Performed Performed By 14...

Page 17: ...rm the repair or replacement This warranty includes travel time not to exceed two hours and mileage not to exceed 50 miles 100 miles round trip but does not include post start up assistance or trainin...

Page 18: ...IMPORTANT SERVICE INFORMATION AccuTemp Product Inc Technical Customer Support Technician is available Monday thru Sunday 7 00am to 7 00pm EST...

Reviews: