Accu-Chek Mobile Quick Start Manual Download Page 2

2. Preparing the finger pricker

Remove the rotatable cap for setting the 
penetration depth 

A

.

Place the cap 

C

 back on again.

Insert a new lancet drum 

B

 (white end 

first). You now have 6 new and sterile 
lancets at your disposal.

Rotate the cap 

D

 of the finger pricker 

until the desired penetration depth is 
level with the indicator. Start with a 
medium penetration depth such as 3.

Roche Diagnostics Limited
Charles Avenue, Burgess Hill
West Sussex, RH15 9RY, 

United Kingdom

Accu-Chek Customer Careline

1)

 

UK Freephone number: 0800 701 000
ROI Freephone number: 1 800 709 600

1)

calls may be recorded for training  purposes

www.accu-chek.co.uk

Roche Diagnostics Australia Pty. Ltd.
31 Victoria Avenue, Castle Hill
NSW 2154, 

Australia

ABN 29 003 001 205
Accu-Chek Enquiry Line: 1800 251 816
www.accu-chek.com.au

What you need to know

Wash your hands with warm water 
and soap. Dry your hands well before 
obtaining blood. 

Apply the blood drop to the centre of the 
test area 

C

. Touch the test area gently 

because the blood is immediately drawn 
up when contact is made.

Read the test result and close the tip 
cover 

D

. The meter automatically turns 

off.

4. Loading a new lancet

Customer Support and Service Centre

W

 

When you are ready to do a test and 
the meter displays 

Apply drop

, ensure 

that you apply the blood drop to the test 
area immediately. Note that liquid can 
evaporate quickly from the tiny drop of 
blood increasing the concentration of 
glucose significantly.

Touch the test area 

gently

 when 

applying blood. Do not press the test 
area onto the finger and do not spread 
the blood drop.

3. Performing a blood glucose test

Open the tip cover 

A

. The meter 

automatically turns on.

Use a small, fresh, well-formed blood 
drop for each blood glucose test and 
apply it to the centre of the test area on 
the cassette.

Blood drop that is well-formed

Blood drop that has spread

Push the lever at the side of the finger 
pricker as far as it will go in direction 

1

 and then back again in direction 

2

 

to load a new lancet.

You can tell that a lancet drum has been 
used because it has a red line visible 
on the white portion. Used lancet drums 
cannot be reused.

Press the finger pricker firmly against 
the selected puncture site. Then press 
the release button 

B

 all the way down 

to obtain a blood drop.

Roche Products (Pty) Ltd.
Diagnostics Division
9 Will Scarlet Road, Ferndale
P.O. Box 1927, Randburg 2125

South Africa

Accu-Chek Customer Care Centre:
080-DIABETES (Dial 080-34-22-38-37)
www.diabetes.co.za

kim_manual_0390

A

kim_manual_0400

kim_manual_0410

C

kim_manual_0430

D

1.

2.

3.

4.

B

kim_manual_0580_gekippt

3.

C

kim_manual_0440

1

2

kim_manual_0090

A

1.

kim_manual_0130_5-9mmol

4.

D

B

2.

New  
lancet drum

Used  
lancet drum

Red line

Reviews: