44
3.7. Adapting the burner to the use of other gas types
The boilers are designed for the type of gas specifically required in order phase, which is also indicated on the
package label and on the boiler rating plate.
Any further processing must be performed by qualified personnel, which will perform the necessary adjusting
and modifications using suitable accessories provided by the manufacturer.
3.7.1. From METHANE to GPL
Edit the parameter P02 from
0
to
1
.
Apply on the boiler a label indicating the adjustment to GPL.
Check and if necessary change the parameters P08, P09, P31, P32
and P33 as indicated in the Table 24
ACCESS TO THE PARAMETERS
Press simultaneously for the cycle time the keys "
" and "
" (
B
+
C
fig. 1) to access the parameters programming mode.
The display will show "TS" for 1 sec, then the number P of TSP for
1 sec followed by the value for 3 sec.
The first parameter that can be changed is P01.
Press the keys "
" or "
" (
F
or
e
fig. 1) to select the parameter
of interest.
Press for the cycle time the key “
” (
D
of the parameter selected.
On the display is shown the previously value set.
Press the keys "
" or "
" (
F
or
E) and
fig. 1to edit the value of the
parameter selected.
Press for the cycle time, the key “
” (
D
setting.
Press simultaneously for the cycle time the keys "
" and "
" (
B
+
C
fig. 1) to exit the parameters programming mode.
Adjust the combustion (CO
2
) as indicated in the section 3.7.3.
3.7.2. From GPL to METHANE
Edit the parameter P02 from
1
to
0
.
Apply on the boiler a label indicating the adjustment to Methane.
Check and if necessary change the parameters P08, P09, P31, P32
and P33 as indicated in the Table 24
ACCESS TO THE PARAMETERS
Press simultaneously for the cycle time the keys "
" and "
" (
B
+
C
fig. 1) to access the parameters programming mode.
The display will show "TS" for 1 sec, then the number P of TSP for
1 sec followed by the value for 3 sec.
The first parameter that can be changed is P01.
Press the keys "
" or "
" (
F
or
E
fig. 1) to select the parameter
of interest.
Press for the cycle time the key “
” (
D
of the parameter selected.
On the display is shown the previously value set.
Press the keys "
" or "
" (
F
or
E) and
fig. 1to edit the value of the
parameter selected.
Press for the cycle time, the key “
” (
D
setting.
Press simultaneously for the cycle time the keys "
" and "
" (
B
+
C
fig. 1) to exit the parameters programming mode.
Adjust the combustion (CO
2