Storage gas water heaters with forced
and sealed conbustion chamber, assisted gas fan

INSTALLATION, USE AND 

MAINTENANCE MANUAL 

GTF SERIES

MOD. 220
30 kW
MOD. 300
34kW
MOD. 400
34kW
MOD. 500
34kW
MOD. 800
34kW

APRIL 2009 Issue (Italy)

GTF SOL SERIES

FOR USE WITH A

SECOND ENERGY SOURCE

MOD. 220
MOD. 300
MOD. 400
MOD. 500
MOD. 800

Summary of Contents for GTF 220

Page 1: ...tion chamber assisted gas fan INSTALLATION USE AND MAINTENANCE MANUAL GTF SERIES MOD 220 30 kW MOD 300 34kW MOD 400 34kW MOD 500 34kW MOD 800 34kW APRIL 2009 Issue Italy GTF SOL SERIES FOR USE WITH A...

Page 2: ......

Page 3: ...DRAINAGE supplied separately As for the different requirements of Installation it can be Concentric with drainage and aspiration to the wall Concentric with drainage and aspiration to the wall Divided...

Page 4: ...DRAINAGE supplied separately As for the different requirements of Installation it can be Concentric with drainage and aspiration to the wall Concentric with drainage and aspiration to the wall Divided...

Page 5: ...tat It is a thermostat capillary with expansion of liquid probe with manual reset once the cause is found manual intervention is necessary The maximum temperature is factory regulated at 95 C Fig 07 5...

Page 6: ...tat It is a thermostat capillary with expansion of liquid probe with manual reset once the cause is found manual intervention is necessary The maximum temperature is factory regulated at 95 C Fig 07 5...

Page 7: ...y the extension poles max 20 mt It s possible to place inside the fume pipe some elbows 90 Reduce the length of 1 mt for each elbow Fig 12 CODE A 01 001 000278 A 01 001 000276 A 03 001 000602 GTF 068...

Page 8: ...y the extension poles max 20 mt It s possible to place inside the fume pipe some elbows 90 Reduce the length of 1 mt for each elbow Fig 12 CODE A 01 001 000278 A 01 001 000276 A 03 001 000602 GTF 068...

Page 9: ...he cable to the electric power respect the polarity of the net phase neutral In case of wrong connection or polarity the water heater does not work COMPONENT UNITS CABLES COLOUR V P EA ER PA SV SB PS...

Page 10: ...he cable to the electric power respect the polarity of the net phase neutral In case of wrong connection or polarity the water heater does not work COMPONENT UNITS CABLES COLOUR V P EA ER PA SV SB PS...

Page 11: ...racket for gas valve Burner Burner bracket Inspection Door chamber gasket Silicon cable protection Combustion chamber door Nozzles collector Upper air blade Electrode Ignition electrode Turbolator bra...

Page 12: ...racket for gas valve Burner Burner bracket Inspection Door chamber gasket Silicon cable protection Combustion chamber door Nozzles collector Upper air blade Electrode Ignition electrode Turbolator bra...

Page 13: ...CES mm A Under window 600 B Under ventilation opening 600 C Under the eaves 300 D Under the balcony 300 E From adjacent window 400 F From opening of adjacent ventilation 600 G From pipes 300 H From pi...

Page 14: ...CES mm A Under window 600 B Under ventilation opening 600 C Under the eaves 300 D Under the balcony 300 E From adjacent window 400 F From opening of adjacent ventilation 600 G From pipes 300 H From pi...

Page 15: ...to a wrong calibration of the pressostat and so is not given the consent to end the cycle For safety and warranty reasons it is recommended when replacing fault components to use only genuine compone...

Page 16: ...to a wrong calibration of the pressostat and so is not given the consent to end the cycle For safety and warranty reasons it is recommended when replacing fault components to use only genuine compone...

Page 17: ...nds the opening of the valve gas and the spark of the electrode At the moment of the ignition the flame is noticed within 10 second otherwise it goes in block it can easily happens in a new installati...

Page 18: ...NOTE...

Page 19: ......

Page 20: ...A2B Accorroni E G s r l Via d Ancona 37 60027 Osimo An Tel 071 723991 r a Fax 071 7133153 web site www accorroni it e mail a2b accorroni it...