background image

10

www.acclaimlighting.com

< IP Settings

< IP Settings

IP:002.003.004.005

IP:002.003.004.005

Mask:255.000.000.000

Mask:255.000.000.000

<         Settings

Art-Net

<         Settings

Art-Net

Net:000

Net:000

Sub-Net:00

Sub-Net:00

Universe:00 Poll:Yes

Universe:00 Poll:Yes

<      Settings

Lock

<      Settings

Lock

Lock Time:  30s

Lock Time:  30s

Display:Off

Display:Off

<         Setti

Factory

<         Setting

Factory

Default: No?

Default: No?

V1.07 Update: N

V1.07 Update: No?

Art-Net Port Status

Art-Net Port Status

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

THE MAIN MENU 

The main menu is where all of the configuration details for Pixel Driver 400 are located.

TO UNLOCK AND USE A MENU PAGE

1  From the standby screen (or blank display, if the backlight is off ), press and release the 

rotary dial. The Art-Net Setting page will be displayed:

2  Rotate the dial clockwise or counterclockwise to move between the four menu pages.
3  When the required page is shown, press and release the dial to unlock that page.
4  Rotate the dial to move the flashing cursor between the options within the page.
5  When the flashing cursor is over the required option, press and release the dial.
6  Rotate the dial to change the value of the option. 
7  Press and release the dial to fix the chosen value of the option.
8  Repeat steps 4 to 7 for all options that need adjustment.   

Notes: 
Some pages require you to lock them again before your configuration changes are enacted.
After a period of inactivity (selectable between 30 seconds and 8 minutes), the unit will return to 
the standby screen.

TO LOCK AND EXIT A MENU PAGE

1  Within a page, rotate the dial to place 

the cursor over the 

<

 symbol. 

2  Press and release the dial to lock the 

page.

3  Rotate the dial to view other 

pages. 

Press and release the rotary 

dial to enter the main menu. 

Rotate the dial to move between menu pages. Press and release the dial to unlock a page. 

IP:002.003.004.005

IP:002.003.004.005

Mask:255.000.000.000

Mask:255.000.000.000

Move the flashing cursor until 

it covers the 

<

  symbol.

Summary of Contents for Pixel Driver 400

Page 1: ...IP Setting IP Setting IP 002 003 004 005 IP 002 003 004 005 Mask 255 000 000 000 Mask 255 000 000 000 Push rotary Link Activity Power Intertek 5001230 DRY LOCATION ONLY POUR EMPLACEMENTS SECS SEULEMEN...

Page 2: ......

Page 3: ...iew 3 INSTALLATION 5 Mounting 5 Ethernet connections 6 Output port connections 7 Input power wiring 8 CONFIGURATION 9 The front panel 9 The main menu 10 Configuring the unit 11 FURTHER INFORMATION 13...

Page 4: ...o be used SAFETY Ensure that the power input is supplied from a correctly fused earthed and environmentally protected location MAINTENANCE CAUTION Always isolate mains power before starting maintenanc...

Page 5: ...rear panel A Flex Tube Pixel strip can be driven from each SPI port The eight SPI outputs are sub divided into two groups each of which can provide a maximum of 200W across the grouped outputs continu...

Page 6: ...t Setting page within the menu see page 11 The 512 channels of each received Art Net universe are applied to the relevant SPI output ports such that each attached Flex Tube Pixel strip will begin at c...

Page 7: ...ws The brackets can be used in two ways FOR SURFACE MOUNTING On each side of the Pixel Driver 400 casing attach two of the supplied brackets to the holes shown FOR RACK MOUNTING On each side of the Pi...

Page 8: ...d Ethernet Thru Use Ethernet IN to connect the Pixel Driver 400 to your controlling device or network switch and Ethernet Thru to link out to the next Pixel Driver 400 unit if used 1 2 3 Ethernet IN E...

Page 9: ...ixel strip with 24VDC and ground together with an SPI control signal 1 2 3 Ethernet Thru Power 200W Max Ground SPI control signal No connection 24VDC Power 200W Max Power 200W Max 1 2 3 4 5 6 7 8 OUTP...

Page 10: ...er supply which exhibits a trait known as in rush current when first powered on This is caused by the various capacitive components initially topping themselves up with power The in rush current perio...

Page 11: ...input The other two green indicators relate to the Ethernet network links The Link indicator is on whenever a valid network link is sensed The Activity indicator will flash as network activity occurs...

Page 12: ...is shown press and release the dial to unlock that page 4 Rotate the dial to move the flashing cursor between the options within the page 5 When the flashing cursor is over the required option press...

Page 13: ...between 0 and 15 Using these three addresses in combination it is possible to choose from 32 768 separate universes The address that you chose here will define the first of eight consecutive universe...

Page 14: ...03 004 005 Mask 255 000 000 000 Mask 255 000 000 000 Settings Lock Settings Lock Lock Time 30s Lock Time 30s Display Off Display Off 3 Rotate the dial to display the IP Setting page Press and release...

Page 15: ...Do the IP address and subnet mask match those used by the controlling device See page 11 Do the Art Net settings match those used by the controlling device See page 11 Check the standby screen to see...

Page 16: ...PI serial control data suitable for Flex Tube Pixel strips Total power draw across all devices attached to ports 1 to 4 must not exceed 200W 8 3A Total power draw across all devices attached to ports...

Page 17: ...S Weight 12 3 lbs 5 6kg 17 36 441 mm 18 94 481 mm P i x e l D r i v e r 4 0 0 Push rotary Push rotary Intertek 5001230 DRY LOCATION ONLY POUR EMPLACEMENTS SECS SEULEMENT 3 46 88 mm 11 81 300 mm 0 31 8...

Page 18: ...rd party items not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and...

Page 19: ...17 www acclaimlighting com...

Page 20: ...www acclaimlighting com...

Reviews: