Table 10. Status LED commands
Command
Description
Default
Parameters/Range
AISLS1
Status LED function.
4
0 - None
1 - Power on
2 - Loader
3 - Power on and loader
4 - Power on except when
triggered
16 - Brownout detection
(Diagnostic)
32 - Brownout reset
(Diagnostic)
48 - Brownout status -
Detection or reset
(Diagnostic)
64 - Intelli sensor reset
(Diagnostic)
128 - Watchdog reset
(Diagnostic)
AISLS2
Status LED function.
2
0 - None
1 - Power on
2 - Loader
3 - Power on and loader
4 - Power on except when
triggered
16 - Brownout detection
(Diagnostic)
32 - Brownout reset
(Diagnostic)
48 - Brownout status -
Detection or reset
(Diagnostic)
64 - Intelli sensor reset
(Diagnostic)
128 - Watchdog reset
(Diagnostic)
5.6 Triggering
These commands control triggering and untriggering of the ATR110.
Table 11. Triggering commands
Command
Description
Default
Parameters/Range
AISTUT
Automatically untrigger.
0
0
–25000 milliseconds
AISTMD
Convert trigger modes.
Warning:
This is for
advanced users only and
modification may cause the
device to become inoperable.
1
0 - Imager must be
triggered
1 - Imager in
presentation mode