Command
Description
Default
Parameters/Range
AISIOP
Interactive mode option flag.
Only applicable to Interactive mode
(
AISOMD2
).
If this flag is set, then the TRIG
messages from the ATR110 are sent
only on media detect and media
removed, regardless of commands from
the host.
0
0 - Disabled
1 - Enabled
AISRDS
Changes the configuration back to its
default values.
Warning:
This command resets all
parameters to their default values,
including any values specific to your
stored configuration.
-
1
AISFWV
Returns the version of the firmware.
-
-
AIS_WA
Returns the firmware version of the
imager.
-
-
AIS_TD
Returns the timestamp of the firmware
release.
1
-
AIS_BO
Enables or disables barcode reading.
This command is stored in volatile
memory so will return to the default on
power cycle.
1
0 - Off
1 - On
AISDLE
Include DLEs (Data Link Escape).
0
0 - Off
1 - On
AISNRD
Sets a ‘No Read’ message, sent at
defined intervals.
0
0 - Off
1
–60000 milliseconds
232CRD
CTS is raised when a ‘Good Read’
output is received.
0
0 - Off
1 - On
232CTS
Hardware handshaking - requires the
CTS to be high.
0
0 - Off
1 - On
5.5.2 Status LEDs
The ATR110 contains two small orange LEDs on the main circuit board, typically used for debug
purposes only. We recommend turning these off in normal use.
A typical configuration will have these turned off, but the default values will be as below (for
example, when using the
AISRDS
command).
Note
:
You can combine more than one function by adding the function numbers together. For
example, Brownout status and Intelli sensor reset is 48 + 64 = 112.