High Elevations
This appliance may be installed at higher altitudes. Please refer to National Fuel Gas Code ANSI Z223.1/NFPA 54, CSA-B149.1
Natural Gas and Propane Installation Code, local authorities, or codes having jurisdiction in you area regarding derate
guidelines.
US Installations - Refer to the American Gas Association guidelines for the gas designed appliances derating method. For
elevations above 2,000 ft (610 m), input ratings are to be reduced by 4% for each 1,000 ft (305 m) above sea level.
Canadian Installations - When the appliance is installed at elevations above 4,500 ft (1,372 m), the certified high altitude rating
shall be reduced at the rate of 4% for each additional 1,000 ft (305 m).
Failure to follow these instructions will void the warranty.
This appliance must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate
solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems.
Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury,
property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious
injury, property damage or loss of life.
Do not pack the open air spaces with insulation or other materials. This could cause high temperatures and may present
a fire hazard and serious injury, property damage or loss of life. Operation of improperly installed and maintained venting
system could result in serious injury, property damage or loss of life.
PART OVERVIEW
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and
immediately inform your authorized dealer if any damage is found. Do not install any damaged, incomplete, or substitute
parts. Check your packing list to verify that all listed parts have been received.
AA BATTERIES
(4 PACK)
REMOTE
9V BATTERY
BOX
AAA BATTERIES
(3 PACK)
Gas Pressures
Natural Propane (LP)
Inlet Minimum
5.0” w.c.
12.0” w.c.
Inlet Maximum
10.5” w.c.
14.0” w.c.
Manifold Pressure 3.8” w.c.
11.0” w.c.
Gas Specifications & Orifice Size
Fuel Max. Input
BTU/h
Min. Input
BTU/h
Orifice
Size
Nat.
18,500
10,000
#45
LP
17,000
9,000
3/64”
Natural Gas
LP Gas