Abus SHBW10000 Manual Download Page 6

 

English 

 

 

1.  Product introduction 

1.1.  Scope of Delivery 

 

ABUS Z-Wave Multisensor including Battery 

 

Quickguide & Safety instructions 

 

Screws & dowels 

 

1.2.  Device features 

 

 

 

Nr 

Label 

Comment 

LED Indicator 

Status displayed for various processes (inclusion, exclusion, reset) 

Network-Button 

For inclusion / exclusion of the detector in a  gateway, factory reset 

Mounting Plate 

For wall-mounting 

 

1.3.  Operating principle 

The SHBW10000 was developed for use in home automation systems that use the Z-Wave wireless 
standard. The multisensor has the following sensors: 

 

PIR 

 

temperature 

 

atmospheric humidity 

 

lights 

 

The motion sensor lets you know when something moves within a certain range and can then trigger 
various scenes/actions. The device also reports the current room temperature, humidity and 
illuminance. 

In conjunction with configurable scenes, smart functions can also be initiated in addition to monitoring, 
e.g. if temperature <20 degrees, heating on. 

 

 

Summary of Contents for SHBW10000

Page 1: ...ABUS Z Wave 4in1 Sensor Important information and FAQs about this product and other products can be found on the website www abus com Version 1 3 Original operating instructions in English Keep for f...

Page 2: ...It can also be obtained at the following adress ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing GERMANY All contained company names and product designations are trademarks of the respe...

Page 3: ...ust Please refer to the individual devices technical data for more detailed information Ensure that adequate ventilation is always guaranteed no direct sources of heat can affect the device interior d...

Page 4: ...r Pb means that the batteries contain quantities of mercury cadmium or lead which exceed the restrictions set by the EU Directive 2006 66 EG If batteries are not disposed of properly these substances...

Page 5: ...se in systems of different manufacturers 7 2 Overview of functions 8 2 1 Inclusion Add Device 8 2 2 Mounting Installation 9 2 3 Exclusion Remove Device 10 2 4 Reset Factory Reset 10 2 5 Wake up 11 3 A...

Page 6: ...all mounting 1 3 Operating principle The SHBW10000 was developed for use in home automation systems that use the Z Wave wireless standard The multisensor has the following sensors PIR temperature atmo...

Page 7: ...idity has a recognition range of max 5 meters has a battery empty warning function was developed for indoor installation 1 5 Use in systems of different manufacturers Communication is via the Z Wave E...

Page 8: ...k the Add button in your Z Wave App and follow the further instructions Press the Button on the device once The App will show if the Add device process was successful The Status LED will light up for...

Page 9: ...rom the battery compartment Fix the Mounting plate on the wall by screws recommended or adhesive tape Screw the detector onto the mounting plate and ensure that the two holes on the housing point down...

Page 10: ...was not successful 2 4 Reset Factory Reset Keep pressing the Button on the device for more than 5 seconds the flash interval of the Status LED is now accelerated The device is now restored to factory...

Page 11: ...An association group is always linked to an event in the controlling device pressing a key or triggering a sensor When this event occurs a control command usually a BASIC SET is sent to all devices s...

Page 12: ...0 Waiting time from one PIR trigger to the next trigger Adjustable from 5 15300 in seconds Hexadecimal 0x05 0x3BC4 14 1 BASIC SET Command after PIR triggering 0 BASIC SET should be sent after triggeri...

Page 13: ...value 0 disables the report Adjustable from 0 2678400 in seconds The value is always rounded up to the full minute e g 62 seconds value is rounded up to 120 seconds Hexadecimal 0x00 0x28DE80 110 1 Ena...

Page 14: ...n for the time based report If the threshold value was not exceeded the time based report is not sent Adjustable from 1 100 in percent Hexadecimal 0x01 0x64 3 3 Command Classes Supported 1 Association...

Page 15: ...50 PIR Trigger 24 times wakeup per day Range open field m 100 Range building m 20 related to material of walls Temperature Measuring range C 0 40 Humidity Measuring range 0 90 Light sensor Measuring...

Reviews: