3.2. Overview Configuration Parameter
Z-Wave products can be used in the network immediately after inclusion. Through configuration
settings, however, the behaviour of the device can be adapted even better to the requirements of the
application and additional functions can be activated.
Para-
meter
Byte-
size
Funktion
Default-Value
(Decimal)
Description
10
1
Low Battery
Power Level
10
Percentage value from when the low battery
alarm message is to be transmitted.
Adjustable from 10 - 50 in percent
(Hexadecimal: 0x0A – 0x32)
12
1
Sensitivity PIR
10
Sensitivity value of the PIR sensor.
The value 10 is the highest sensitivity.
The value 0 disables the PIR sensor.
Adjustable from 0 - 10
(Hexadecimal: 0x00 – 0x0A)
13
2
Waiting time
between two
PIR triggers
30
Waiting time from one PIR trigger to the next
trigger.
Adjustable from 5 - 15300 in seconds
(Hexadecimal: 0x05 – 0x3BC4)
14
1
BASIC SET
Command after
PIR triggering
0
BASIC SET should be sent after triggering the
PIR.
0 = Disabled
1 = Enabled
(Hexadecimal: 0x00 – 0x01)
15
1
Exchange of
BASIC SET
value and PIR
status
0
Exchange of the BASIC SET value and the PIR
status should take place after a PIR triggering.
0 = A PIR trip sends the BASIC SET
value "256", a PIR alarm termination
sends the BASIC SET value "0"
1 = A PIR trip sends the BASIC SET
value "0", a PIR alarm termination sends
the BASIC SET value "256"
(Hexadecimal: 0x00 – 0x01)
100
1
Reset 101 – 104
-
Resets parameter 101 - 104 to factory setting.
101
4
Temperature
report
Time
7200
The interval time of the temperature report.
The value 0 disables the report.
Adjustable from 0 - 2678400 in seconds
The value is always rounded up to the full
minute. (e.g. 62 seconds -> value is rounded up
to 120 seconds)
(Hexadecimal: 0x00 – 0x28DE80)