Abus ITAC10120 User Manual Download Page 1

 
 
 
 
 
 

ITAC10120 
ITAC10130 

 

 

 
 
 

   

User manual Web Management 

 
 
 

Originalbedienungsanleitung in deutscher Sprache. Für künftige Verwendung aufbewahren. 
 
This user manual contains important information for installation and operation. 
This should be also noted when this product is passed on to a third party. 
Therefore look after these operating instructions for future reference! 

 

Version 05/2019

 

Summary of Contents for ITAC10120

Page 1: ...er Sprache Für künftige Verwendung aufbewahren This user manual contains important information for installation and operation This should be also noted when this product is passed on to a third party Therefore look after these operating instructions for future reference Version 05 2019 ...

Page 2: ...10 3 3 1 VLAN Forwarding 11 3 4 Trunk Management 12 3 5 RSTP 13 3 5 1 STP Basic Concept 13 3 5 2 RSTP 15 3 6 Port Security 16 3 6 1 802 1X certificates 17 4 Web Management 19 4 1 SNMP Settings 19 4 2 Email Alarm 20 4 3 Port Mirror 21 4 4 IGMP Snooping 22 5 Network Statistics 23 5 1 MAC Address 24 6 System Management 25 6 1 IP Address 25 6 2 Log Information 26 6 3 File Management 27 7 PoE Managemen...

Page 3: ...b Management via CLS Port To connect to the web management interface connect a console cable RJ45 R232 serial port 115200 8 N 1 to the CLS port to the PC at the serial port DB9 and enter the following data into the browser The default factory settings are IP Address 192 168 1 200 User admin Password admin 2 Reset Restart Press the reset button to restart the switch Reset to default factory setting...

Page 4: ... MAC address table aging time 300 Seconds Port Ports Status Enable Ports Speed Rate Auto negotiation Ports duplex mode Auto negotiation Flow Control Open Trunking Port does not converge Port Speed Limitation No limitation for Speed Port Link Type Access Management VLAN VLAN 1 VLAN Function Mode Port based VLAN MAC Binding No Binding RSTP RSTP Function Close Network Management SNMP Close ...

Page 5: ...en it will start to count from 0 00 1970 PC Time Computer current time Device Name Enter the Name of the device Network identification device used to facilitate the integrated management tools such as SNMP to judge different equipment Contacts Enter maintenance personnel s contact information Contact Address Enter maintenance personnel s contact information MAC Address MAC Hardware address of the ...

Page 6: ...negotiation mode by default Possible settings including full duplex mode half duplex mode and Auto negotiation mode Flow Control Enabled by default Enable or disable Flow control When two switches have enabled the flow control function if one of the two switches are congested it will send a message to the other switch to notify it to temporarily stop sending messages or slow down the sending speed...

Page 7: ...ckets The accuracy is 1Mbps The range is For downlink ports 1 1000Mbps For uplink ports 1 1000Mbps Description Bandwidth Settings on off Off by default Enable or disable the port speed limit Port Range The port for speed limit Input Rate The max input rate of each port Limited type Port limited type including all Unicast packets and multicast ...

Page 8: ...Port VLAN page you can observe and change the VLAN settings Description Link type Access port belongs to one VLAN which is normally used for connecting devices By default all ports are Access ports Trunk port belongs to multiple VLANs and can receive and send multiple VLAN packets It is normally used to connect network devices Default VLAN ID Enter the ID number generally 1 4094 VLAN Forwarding li...

Page 9: ...3 3 1 VLAN Forwarding On the VLAN VLAN forwarding page you can observe the current port VLAN forwarding settings Description VLAN ID Change VLAN ID VLAN Name Change VLAN name ...

Page 10: ...orts with the following cases cannot be added to an convergence group Port with 802 1X function The mirror port Port with MAC address binding In the same convergence group the port speed duplex mode and basic configuration must be consistent STP consistent configuration including STP ports on off STP priority STP cost whether to open loop guard and root guard or edge ports QoS configuration is con...

Page 11: ...1D board meaning of STP includes IEEE 802 1D defined STP and various enhanced spanning tree protocol produced on the basis of STP such as RSTP protocol 3 5 1 STP Basic Concept The root bridge STP introduces the concept of root bridge since network structure tree must have a root Only one root bridge and the root bridge will change when the network topology changes so the root bridge is not fixed T...

Page 12: ... received and processed no user traffic forwarded Disabled Consider blocking or link disconnection The designated bridges and designated ports Classification Designated Bridge Designated Port For equipment Equipment connecting directly with switch and responsible to transfer BPDU message to switch Port used by designated bridge to transfer BPDU message to switch For LAN Responsible to transfer BPD...

Page 13: ...The forward delay of a switch port status in transition status listening and learning Path expenditure Setting port path cost only setting when port default path cost on off status Port link cost with port priority and port ID form port ID to compare Value range 1 200000000 0 means automatic check Port priority By default port priority is 128 The priority of port in network bridge with port priori...

Page 14: ...m the general MAC address Once a static address is added the address will remain in effect until be deleted VLAN ID Port corresponding VLAN ID number Port Select a static MAC address to forward a port You can only specify one forwarding port Attention This feature is a security mechanism which requires high attention to the settings Do not use a multicast address Do not enter the reserved MAC addr...

Page 15: ... lot of advantages All the business is not restricted by authentication 802 1X Three Main Parts Application supplicant User and Client which want to get the certification Authentication server A typical example for the RADIUS server Certification System authenticator Between the end devices such as wireless access points switches etc They can play at the same time equipment system and authenticati...

Page 16: ...billing set the IP address domain is equipment can access to Control mode Compulsory licensing model respectively and the automatic mode mandatory unauthorized mode Port Control mode MAC Based Max ID list Scope 1 4096 Attention Between the applicant and the authentication system using MD5 inquiry do not support others If the network connection properties are without authentication option please se...

Page 17: ... packets and send the response packets back to the NMS On the Network management SNMP Settings page you can enable disable the SNMP settings Description SNMP Gateway Agent send the network IP address from receiver who send abnormal alert SNMP version Only support V1 V2 V3 version Read only community name A SNMP community named after a string the group only has permission to operate Read write comm...

Page 18: ...t provide POP3 Email delivery service to our devices Email Accounts The account name for logging in email server E mail Password The password to the account name for logging in email sever Recipient Address The email address used to inform recipients of abnormal events Email Reply Address The email address that can help solve abnormal events Mail interval The interval time that regularly send log ...

Page 19: ...management port Mirror page which could modify port Mirror function settings Description Port Mirror The default is off Turn Port Mirror Function on off Monitor Port Select Port for monitoring Mirror Port These ports collect designated direction data from be monitored ports Data Collection Specifies the monitor port data direction all data data import and export data Attention This feature must be...

Page 20: ...rk Management IGMP Snooping Page Modify and setting IGMP Snooping function Description IGMP Snooping The default is disabled Enable or disable the Multicast Snooping function IGMP Inquiry Enable or disable the IGMP Multicast Inquiry function IGMP Query interval Set interval for query interval Member Existing Time Set Existing multicast Member survival time Unknown multicast group forwarding table ...

Page 21: ...ast Package The sent received address is the number of packets in the broadcast address Receive Frame Error Package Error package numbers due to various wrong reasons sent and received by ports Send Frame Singlecast Package The sent address is the number of packets in the unicast address Send Frame Multicast Package The sent address is the number of packets in the multicast address Send Frame Broa...

Page 22: ...e basic and premise for data frame fast forwarding On the Network statistics MAC table page you could check MAC address of each port Description Inquiry by physical port Enter MAC address to check filter Inquiry by MAC address type MAC address type consists of static MAC address and dynamic MAC address Attention Multicast MAC address table is displayed in IGMP snooping table All these address tabl...

Page 23: ...nt On this page you can modify or add one user with password Description User Index User index indicates the group of users There are three user indexes in drop down table Visit Level Administrator View and set all settings User View and set only some functions User name The identification of the user Input Password Enter user password Confirm Password Confirm above entered password ...

Page 24: ... information On the System management Log information page you could check the time and type of event Description Log Sever address The server address receiving the log information Record lowest grade There are eight optional levels error information notification information to be logged information in need of quick reaction serious information information that cannot be used in system normal but ...

Page 25: ...oot system Description Configuration File Backup switch configuration File format cfg Restore switch configuration File format cfg Software Update Select file to perform firmware update Restore Factory Defaults Set switch to default settings except for IP address user name and password System Reboot Restart system and return to system status page ...

Page 26: ...will power off ports with lower priority Reserved rate Reservation power cannot be used for distribution but can be used for PD consumption caused by overload change The default is 15 of the total power The larger this number the smaller the risk of system overload So the usable power for distribution and PD quantity become less On the contrary the more the number of PD access the greater risk of ...

Page 27: ...le high Supply priority when the system is overloaded the power supply of the port with low priority will be turned off firstly Power limit Set the output power limit for single port The port will power off when actual output power exceeds limit On Off Turn PoE Port Power on off Setting Set port priority for maximum power consumption ...

Page 28: ...highest priority is 7 then to 6 5 4 3 2 1 0 802 1P Scope The default is 0 Possible values 0 7 Priority Set que priority The highest priority is 7 then to 6 5 4 3 2 1 0 DSCP7TOS QoS On the QoS Setting DSCP TOS QoS page you can modify the setting DSCP TOS QoS Description DSCP TOS QoS The default is off Turn DSCP TOS QoS function on off DSCP Scope Identifies TOS scope 0 63 DSCP Priority Set TOS Prior...

Page 29: ...icht dem technischen Stand bei Drucklegung Änderung in Technik und Ausstattung vorbehalten Imprint These operating instructions are published by ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing Germany No reproduction including translation is permitted in whole or part e g photocopy microfilming or storage in electronic data processing equipment without the express written consent o...