EN
C.
Scope of delivery
•
Wireless smoke alarm / heat detector
•
Installation material
•
2 x CR123 3V lithium batteries
•
Installation and Operating Instructions, available
in several languages
D.
Technical data
Item No.
FURM30000
Smoke alarm
Optical sensor for detecting smoke
Heat detector
Dual thermosensor for measuring temperature increase (5°C a
minute) and limit value (65°C)
Certification
EN14604:2005/AC:2008
Operating modes
Smoke + Heat (OR logic)
Only smoke
Only heat
Signals
Acoustic (Piezo) and visual (LED)
Volume of the warning signal
Min. 85 dB(A) at 3m
Sound frequency
3.6 kHz
Standby power consumption:
0.02mA
Alarm power consumption:
100mA
Battery life:
Approx. 3 years
Battery type:
2 x CR123 3V lithium batteries
“Dead battery” error message:
< 2.5 V
“Dead battery” warning:
30 days before complete discharge
Signal in event of dead battery:
A beep every 30 seconds
Operating temperature:
-10°C to 40°C
Humidity during operation:
10% to 85% RH, no condensation or icing
Environmental class
II (EN50131-1)
Protection class
IP 31
Colour:
White
Dimensions:
Diameter: 108 mm / Height: 53 mm
Weight:
175 g net
Wireless frequency operating
modes
Unidirectional (one-way)
Nominal centre frequency
868.65 MHz
Supervision monitoring
Approx. every 15 min.
Wireless transmission power
10mW
Wireless range
Up to 300 m (unobstructed)
HF immunity
10 V/m (EN50130-4:2011)
- 37 -