27
Test notifications (test and poll notifications)
The AZWG10200-PSTN/IP CONVERTER has eight internal timers that are
used to monitor the connection paths via automatic test, poll and interval-
based notifications. The timers are easy to configure using pre-settings in
line with the EN risk classes. Poll notifications are used when the interval is
short. These are monitored by the monitoring station receiver. Poll
notifications are used in the DP classes. Timer 1 is the primary poll and
timer 2 is the redundant poll in this case. If the primary path fails, timer 2
takes over the interval from timer 1. When the primary path is restored,
timer 2 is reset. Test notifications are used for classes SP-1 and SP-2. A
test notification is monitored by the monitoring station software rather
than the receiver. The AZWG10200-PSTN/IP CONVERTER sends the test
notification as a VdS, Contact ID or SIA RP, TX, RX report. When an RX
report is sent and there is a GPRS connection, the ICCID number of the
SIM card and the current provider can also be sent.
Time setting, enabling of timer via menu selection:
o
Not active: timer is disabled
o
Active: timer is enabled; can be set via the
'Advanced timer settings' menu
o
Poll: poll notifications are enabled; can be set via the
'Poll times' menu
Interval, time interval in hours, minutes and seconds. The
poll interval time is automatically set when an EN risk class
is selected and given a green background. When a timer is
enabled (no poll), the desired interval must be set in the
'Advanced timer settings' menu.
Sequence: notifications are processed as per the sequence
set in the 'Transmission' tab.
Notification, selection of poll, test and interval notifications: