IsoSplitter
®
Frequency to DC Signal Splitter/Isolator/Transmitter, Factory Configured
APD 7393
1 Input:
0-25 Hz to 0-20 kHz
2 Outputs:
0-1 V to 0-10 V, ±1 V to ±10 V, 0-1 mA to 20 mA, 4-20 mA
O
One Input to Two Outputs with Full Isolation
O
Zero and Span Output Calibration Potentiometers
O
Full 1200 V Input/Output /Power Isolation
O
Input and Output LoopTracker
®
LEDs
O
Output Test Button for Each Channel
O
Built-In Loop Power Supplies for Sink/Source I/O
Q
Split, Convert, Boost, and Rescale Process Signals
Q
Split Process Signals for Control and Validation
Q
Interface a Process Signal with Multiple Panel Meters,
PLCs, Recorders, Data Acq., DCS, & SCADA Systems
Applications
Options—add to end of model number
R1
Channel 1 I/O reversal (ie. 4-20 mA in to 20-4 mA out)
R2
Channel 2 I/O reversal (ie. 4-20 mA in to 20-4 mA out)
R3
Channel 1 and channel 2 I/O reversal
M19
Channel 1 high voltage output >10 V up to 20 V
M29
Channel 2 high voltage output >10 V up to 20 V
M39
Channel 1 and channel 2 high voltage output
U
Conformal coating for moisture resistance
Accessory—order as separate line item
API BP4
Spare removable 4 terminal plug, black
Description
The APD 7393 IsoSplitter accepts a frequency input and
provides two optically isolated DC voltage or current outputs
that are linearly related to the input. The input range and each
output range are independent and can be specified as required.
This provides an economical solution when one signal must be
sent to two different devices.
Typical applications include isolation, output splitting, output
device separation and redundancy (i.e. to prevent failure of
the entire loop if one device fails), or a combination of these.
The input signal is filtered, amplified, split, and then passed
through an opto-coupler to the output stages. Full 4-way isola-
tion (input, output 1, output 2, power) make this module useful
for ground loop elimination, common mode signal rejection,
and noise pickup reduction.
I/O Sink/Source Versatility
Standard on the APD 7393 is a 15 VDC sensor excitation supply
for the input channel and 20 VDC loop excitation supplies for
each output channel. These power supplies can be selectively
wired for sinking or sourcing allowing use with any combina-
tion of powered or unpowered milliamp I/O devices.
LoopTracker
API exclusive features include three LoopTracker LEDs (green
for input, red for each output) that vary in intensity with
changes in the process input and output signals.
These provide a quick visual picture of your process loop at all
times and can greatly aid in saving time during initial startup
and troubleshooting.
Output Test
An API exclusive feature includes output test buttons for each
channel to provide a fixed output (independent of the input)
when held depressed. A test button is provide for each output
channel. The output test greatly aids in saving time during
initial startup and/or troubleshooting.
The test output level for each channel is potentiometer adjust-
able from 0 to 100% of the output span.
Terminals are provided to operate the test functions remotely
for each channel. This also allows use as a remote manual
override to provide a temporary fixed output if desired.
Frequency Input Range
Factory configured, please specify input range
Frequency:
0-25 Hz to 0-20 kHz
Any waveform with 5 microsecond min. pulse, 100 mV min.
amplitude change, 100 mV to 150 V
RMS
amplitude
Input Impedance
10 k
W
nominal (maximum sensitivity)
100 k
W
nominal (minimum sensitivity)
Input Sensitivity/Hysteresis
Multi-turn potentiometer for sensitivity adjustment
Maximum sensitivity:
±25 mV typical
Minimum sensitivity:
±2.5 V typical
Input Protection
Normal mode protection:
200% of input rating
Common mode protection:
600 V input to ground
Sensor Power Supply
15 VDC ±10%, regulated, 25 mADC, Max. ripple, less than 10
mV
RMS.
May be used to power sensor.
LoopTracker
Variable brightness LEDs indicate I/O loop level and status
One for input, one for each output
Channel 1 and Channel 2 DC Output Ranges
Factory configured, please specify for each output channel
Voltage:
0-1 VDC to 0-10 VDC, 10 mA max
up to 20 VDC with M19, M29, M39
Bipolar voltage: ±1 VDC to ±10 VDC
Current:
0-1 mADC to 0-20 mADC, 4-20 mADC
20 V compliance, 1000
W
at 20 mA
Output Loop Power Supplies
20 VDC nominal, regulated, 25 mADC for each output channel
May be selectively wired for sinking or sourcing mA output
Output Calibration
Multi-turn zero and span potentiometers for each output channel
±15% of span adjustment range typical
Output Test/Override
Front momentary buttons or external contact closures for
each channel to set output test levels.
Each output test level potentiometer adjustable 0-100% of span
Output Ripple and Noise
Less than 10 mV
RMS
Linearity
Better than ±0.1% of span
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than ±0.04% of span per °C stability
Isolation
Full 4-way, 1200 V
RMS
minimum
Installation Environment
IP 40, requires installation in panel or enclosure with ade-
quate ventilation
For use in Pollution Degree 2 Environment
Mount vertically (as shown in picture) to a 35 mm DIN rail
allowing minimum 1" (25 mm) above and below housing
vents for air circulation.
Power
85-265 VAC, 50/60 Hz or 60-300 VDC, 6 W maximum
D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 6 W maximum
How to Order
Models are factory ranged. See I/O ranges above left.
Please specify ranges and options on order
Input range
Channel 1 output range
Channel 2 output range
See options at right
Model
Description
Power
APD 7393
IsoSplitter
1 input to
2 outputs
85-265 VAC, 50/60 Hz or
60-300 VDC
APD 7393 D
9-30 VDC or 10-32 VAC
Options and Accessories
Dimensions and Connectors
1.78" W x 4.62" H x 4.81" D
45 mm W x 117 mm H x 122 mm D
Eight 4-terminal removable connectors, 14 AWG max wire size
Free Factory
I/O Setup!
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
File E145968
85-265 VAC, 60-300 VDC
model only
© 02-20
api-usa.com
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
Fax: 800-949-7502
A
A
BSOLUTE
BSOLUTE
P
P
ROCESS
ROCESS
I
I
NSTRUMENTS
NSTRUMENTS
Quick Link:
api-usa.com/7393
Removable Plugs
Sink or Source
mA Output for
Each Channel
Output LoopTracker
LED for Each
Channel
Input LoopTracker
LED
Zero and Span for
Each Channel
Connect Sink or
Source mA Input
Custom I/O Ranges
Adjustable Output
Test Function for
Each Channel
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
25 26 27 28
29 30 31 32
17 18 19 20
21 22 23 24
See Wiring
Diagrams on
Next Page
Universal Power
Applications Link
api-usa.com/apps
Pb
Lead
Free