 Intrinsically Safe Digital Pressure Gauges, with Min/Max Options 

DPG2000B D4 and M0, M1 Series

 

O

±0.25% Test Gauge Accuracy

 

O

316L Stainless Steel Sensor

 

O

All Metal Housing

Agency Approval

Factory Mutual Approved Intrinsically Safe for Hazardous Locations 

USA & Canada 

IS Class I, Division 1, Groups A, B, C, D 

T3C Ta = –40°C to 82°C; T4 Ta = –40°C to 66°C

CL I Zone 0 AEx/Ex ia IIC  

T3 Ta = –40°C to 82°C; T4 Ta = –40°C to 66°C

Ranges and Resolution

See table below. Select range and default engineering unit.  

Units may be changed to any listed under the same sensor range. 

Resolution is fixed and limited to available display digits.

Display

3 readings per second nominal display update rate 

4 digit LCD, 0.5" H and 5 character 0.25" H alphanumeric 

BL

:   Red LED backlight. Keypress activates backlighting for 1  

 

minute if ambient light is insufficient.

Accuracy

Accuracy includes linearity, hysteresis, repeatability 

Standard accuracy:  ±0.25% of full scale ±1 least significant digit 

HA

 accuracy option: ±0.1% FS ±1 LSD, see ranges for availability 

Sensor hysteresis:  ±0.015% FS, included in accuracy 

Sensor repeatability: ±0.01% FS, included in accuracy

Auto Shutoff

5, 10 , 30 minutes, or on/off. User selectable 1 minute to 8 hrs 

Memory Options

Min/max can be user configured to be individually enabled or dis-

abled, readings saved or cleared at power off  

Std:  Min/max enabled

M0

:  Min/max turned off in user setup 

M1

:  Peak reading only gauge for tire pressure

Calibration

Non-interactive zero, span, and linearity, ±10% of range Internal 

setup/calibration buttons, internal lockout switch.

Controls and Functions

Front button turns gauge on or off, zeros gauge reference gauges, 

and cycles through min/max functions (if enabled) 

Internal buttons for engineering unit selection, auto shutoff time, 

min/max setup, calibration 

Internal lockout switch to disable setup and calibration

Batteries

Two 1.5 V AAA Panasonic LR03 alkaline cells 

B

Approx. 1000 hours 

BL

:  Approx. 150 to 1000 hours depending on backlight usage 

Low battery symbol on display when batteries need replacement

Weight

9 ounces (approx.), shipping wt. 1 pound (approx.) 

Housing Materials and Circuit Board Protection

Epoxy powder coated aluminum case, rear cover, and bezel. Front 

and rear rubber gaskets, polycarbonate label. 

Stainless steel stiffener plate to reinforce sensor area.  

Conformal coating on circuit boards for moisture resistance.

Connection and Material

1/4" NPT male fitting. All wetted parts are 316L stainless steel.

Overpressure, Burst, Vacuum

2 X pressure range for 3 psi to 2000 psi sensors

5000 psig for ranges using 3000 psig sensor 

7500 psig for ranges using 5000 psig  sensor 

Over-range display 112.5% FS: 

I – – –

 or 

I –.–.–.–

Under-range display (non-vacuum sensors): 

–Err

Vacuum service: 

15 psia, ±15 psig, 15 psig, 30 psia,  

 

100 psig, 100 psia, 200 psig sensors

Burst: 4 X sensor pressure rating or 10,000 psi, whichever is less

Environmental

Storage temperature: 

–40 to 203°F (–40 to 95°C)

Operating temperature: 

–4 to 185°F (–20 to 85°C)

Compensated temperature:  32 to 158°F (0 to 70°C)

Sensor Ranges and Engineering Units  

* -HA option not available

 

Range codes are rounded off

3 psig 

*

Res

15 psig vac 

*

Res

30 psia

Res –15V100psig 

*

Res

300 psig

Res

3PSIG

.001

100KPAVAC

.1

2KGCMA

.001

100PSIVAC

.1

300PSIG

.1

6INHGG

.001

0.1MPAVAC

.0001

2ATMA

.001

100PSICPD

.1

610INHGG

.1

85INH2OG

.1

1BARVAC

.001

30 psig

Res

200INHGVAC

.1

4800ZING

1

50ZING

.01

1KGCMVAC

.001

30PSIG

.01

2770INH2OVAC

1

700FTH2O

.1

210GCMG

.1

1ATMVAC

.001

60INHGG

.01

1600ZINVAC

1

2000KPAG

1

150MMHGG

.1

15 psig

Res

850INH2OG

1

5200MMHGVAC

1

2MPAG

.001

150TORRG

.1

15PSIG

.01

480ZING

.1

5200TORRVAC

1

20BARG

.01

200MBARG

.1

30INHGG

.01

2100GCMG

1

700KPAVAC

1

20KGCMG

.01

200CMH2OG

.1

400INH2OG

.1

1600MMHGG

1

0.7MPAVAC

.001

20ATMG

.01

2000MMH2OG

1

240ZING

.1

1600TORRG

1

7BARVAC

.01

500 psig

Res

7FTH2O

.001

1000GCMG 

1

2000MBARG

1

7KGCMVAC

.01

500PSIG

.1

20KPAG

.01

760MMHGG

.1

2100CMH2OG

1

7ATMVAC

.01

1020INHGG

1

5 psig 

*

Res

760TORRG

.1

70FTH2O

.01

100 psig

Res

1150FTH2O

1

5PSIG

.001

1000MBARG

1

200KPAG

.1

100PSIG

.1

3500KPAG

1

10INHGG

.01

1000CMH2OG

1

0.2MPAG

.0001

200INHGG

.1

3.5MPAG

.001

140INH2OG

.1

35FTH2O

.01

2BARG

.001

2770INH2OG

1

35BARG

.01

80ZING

.1

100KPAG

.1

2KGCMG

.001

1600ZING

1

35KGCMG

.01

350GCMG

.1

0.1MPAG

.0001

2ATMG

.001

7000GCMG

1

35ATMG

.01

260MMHGG

.1

1BARG

.001

60 psig

Res

5200MMHGG

1

1000 psig

Res

260TORRG

.1

1KGCMG

.001

60PSIG

.01

5200TORRG

1

1000PSIG

1

350MBARG

.1

1ATMG

.001

120INHGG

.1

7000MBARG

1

2040INHGG

1

350CMH2OG

.1

±15 psig 

*

Res

1660INH2OG

1

7000CMH2OG

1

2300FTH2O

1

3500MMH2OG

1

±15PSIVAC

.01

960ZING

1

230FTH2O

.1

7000KPAG

1

12FTH2O

.01

15PSICPD

.01

4200GCMG

1

700KPAG

.1

7MPAG

.001

35KPAG

.01

±30INHGVAC

.01

3100MMHGG

1

0.7MPAG

.0001

70BARG

.01

15 psia

Res

±400INH2OVAC

1

3100TORRG

1

7BARG

.001

70KGCMG

.01

15PSIA

.01

±240ZINVAC

.1

4100MBARG

1

7KGCMG

.001

70ATMG

.01

30INHGA

.01

±1000GCMVAC

1

4200CMH2OG

1

7ATMG

.001

2000 psig

Res

400INH2OA

.1

±760MMHGVAC

1

140FTH2O

.1

–15V200 psig 

*

Res

2000PSIG

1

240ZINA

.1

±760TORRVAC

1

400KPAG

.1

200PSIVAC

.1

4070INHGG

1

1000GCMA

1

±1000MBARVAC

1

0.4MPAG

.0001

200PSICPD

.1

4600FTH2O

1

760MMHGA

.1

±1000CMH2OVAC

1

4BARG

.001

400INHGVAC

.1

14MPAG

.01

760TORRA

.1

±100KPAVAC

.1

4KGCMG

.001

5500INH2OVAC

1

140BARG

.1

1000MBARA

1

±0.1MPAVAC

.0001

4ATMG

.001

3200ZINVAC

1

140KGCMG

.1

1000CMH2OA

1

±1BARVAC

.001

100 psia

Res

1400KPAVAC

1

140ATMG

.1

100KPAA

.1

±1KGCMVAC

.001

100PSIA

.1

1.4MPAVAC

.001

3000 psig

Res

0.1MPAA

.0001

±1ATMVAC

.001

200INHGA

.1

14BARVAC

.01

3000PSIG

1

1BARA

.001

30 psia

Res

2770INH2OA

1

14KGCMVAC

.01

6100INHGG

1

1KGCMA

.001

30PSIA

.01

1600ZINA

1

14ATMVAC

.01

6900FTH2O

1

1ATMA

.001

60INHGA

.01

7000GCMA

1

200 psig

Res

20MPAG

.01

15 psig vac 

*

Res

850INH2OA

1

5200MMHGA

1

200PSIG

.1

200BARG

.1

15PSIVAC

.01

480ZINA

.1

5200TORRA

1

400INHGG

.1

200KGCMG

.1

30INHGVAC

.01

2100GCMA

1

7000MBARA

1

5500INH2OG

1

200ATMG

.1

400INH2OVAC

.1

1600MMHGA

1

7000CMH2OA

1

3200ZING

1

5000 psig

Res

240ZINVAC

.1

1600TORRA

1

700KPAA

.1

480FTH2O

.1

5000PSIG

1

1000GCMVAC

1

2000MBARA

1

0.7MPAA

.0001

1400KPAG

1

35MPAG

.01

760MMHGVAC

.1

2100CMH2OA

1

7BARA

.001

1.4MPAG

.001

350BARG

.1

760TORRVAC

.1

200KPAA

.1

7KGCMA

.001

14BARG

.01

350KGCMG

.1

1000MBARVAC

1

0.2MPAA

.0001

7ATMA

.001

14KGCMG

.01

340ATMG

.1

1000CMH2OVAC

1

2BARA

.001

14ATMG

.01

How to Specify

Display Memory

DPG2000B

 range -

D4

-time-options

-

Min/max

DPG2000BBL

 range -

D4

-time options

backlit

Min/max

DPG2000B

 range -

D4

-

M0

-time-options

-

Min/max off

DPG2000BBL

 range -

D4

-

M0

-time-options

backlit

Min/max off

DPG2000B

 range -

D4

-

M1

-time-options

-

Peak read

DPG2000BBL

 range -

D4

-

M1

-time-options

backlit

Peak read

 

G = gauge reference pressure 

 

CPD = compound; inHg vacuum, psi pressure 

 

VAC = gauge reference vacuum 

 

A = absolute reference

 

psi = PSI 

  inHg = INHG 

 oz/in

2

 = ZIN 

 inH

2

O = INH2O 

 ftH

2

O = FTH2O 

  mmHg = MMHG 

 

torr = TORR 

 mmH

2

O = MMH2O 

 kg/cm

2

 = KGCM 

 g/cm

2

 = GCM 

 

kPa = KPA 

  MPa = MPA 

  mbar = MBAR 

 

bar = BAR 

 cmH

2

O = CMH2O 

 

atm = ATM

Range

—See table at left. Select a range code for default units. 

Please specify if vacuum gauge requires a minus sign.

Time

—auto shutoff time

5

5 minutes. Default if not specified.

10

10 minutes

30

30 minutes

ON

No auto shutoff. On/off via front button.

xH

Custom shutoff time where x = up to 8 hours 

Options

—add to end of model number. See price list for details.

HA

High accuracy, ±0.1% FS ±1 LSD. See range table.

PM

Panel mount, 4.1" x 4.1"

TP

Top port, gauge port on top of case

CD

Calibration data; 5 test points and date 

NC

NIST traceability documentation, 5 points and date

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

Made in USA

Quick Link 

cecomp.com/is

Accessories

—order separately

CON14SS

Quick connector to install or remove gauge with-

out tools. 304 stainless steel, urethane seal.

SCR14SS

Filter screen fitting keeps debris out of gauge 

sensor. For food vacuum packaging applications. 

303SS body, 100 micron 304SS screen. 

RB

High visibility orange rubber boot protects gauge 

for portable applications. Not available with NEMA 

4X models.

TP

Top gauge port. Primarily used with tire pressure 

applications. Not available with NEMA 4X models.

© 08-18

cecomp.com

1220 American Way Libertyville, IL 60048 

800-942-0315

CECOMP

 

Div. of

 

A

BSOLUTE

 P

ROCESS

 I

NSTRUMENTS

Summary of Contents for Cecomp DPG2000B Series

Page 1: ... 01 100 psig Res 1150FTH2O 1 5PSIG 001 1000MBARG 1 200KPAG 1 100PSIG 1 3500KPAG 1 10INHGG 01 1000CMH2OG 1 0 2MPAG 0001 200INHGG 1 3 5MPAG 001 140INH2OG 1 35FTH2O 01 2BARG 001 2770INH2OG 1 35BARG 01 80ZING 1 100KPAG 1 2KGCMG 001 1600ZING 1 35KGCMG 01 350GCMG 1 0 1MPAG 0001 2ATMG 001 7000GCMG 1 35ATMG 01 260MMHGG 1 1BARG 001 60 psig Res 5200MMHGG 1 1000 psig Res 260TORRG 1 1KGCMG 001 60PSIG 01 5200T...

Page 2: ...nd then release the but ton Both maximum and minimum values are cleared and the gauge returns to the normal operating mode M0 Models are configured with minimum and maximum func tions disabled One or both can be enabled or disabled in the User Configuration mode M1 Models are peak reading gauges that only display and captures maximum readings Press and hold the button for about 1 second until MAX ...

Page 3: ...vent accidental or unauthorized changes The selected shut off time is stored in non volatile memory and will be retained even with the battery off or batteries removed With the gauge powered up press and hold the DOWN button Release the button when the auto shutoff time is displayed on the upper section The lower display will indicate AST M if the time displayed is in minutes and AST H if it in ho...

Page 4: ...sure signal It may take more than one of these small changes to result in a single digit change on the display To make larger changes press and hold the appropriate UP or DOWN button After about one second the display will begin to change continuously Release the button to stop Then make fine adjustments by pressing and quickly releasing the appropriate button Gauge Reference Pressure Gauges Apply...

Reviews: