background image

DC to DC Math Function Transmitters, Isolated 

API 4400 G through API 4408 G

Input:

 

0-100 mV to 0-10 VDC or 0-1 mA to 0-20 mA

Output:

 

0-1 V to ±10 VDC or 0-1 mA to 4-20 mA

 

O

Add, Subtract, or Average up to 4 DC Inputs

 

O

Factory Set Custom I/O Ranges

 

O

Easy-to-Install Plug-In Design

 

O

Full 2000 V Input/Output/Power Isolation

 

O

Input and Output LoopTracker

®

 LEDs

 

O

Output Test Button

 

Q

Add, Subtract, Average Flow Signals

 

Q

Average Multiple Signals

Applications

Description 

The API 4400 G through API 4408 G are factory configured to 
accept two to four DC voltage or current inputs and provide 
an optically isolated DC voltage or current output that is pro-
portional to the sum, average and/or difference of the inputs 
depending on the model.
The A, B, C, and D inputs should be the same type, and mixed 
input ranges are allowable. Consult the factory when selecting 
mixed input ranges. 
Inputs are converted to a percentage and then the math 
function is applied. Consult the factory if true voltage math 
is required.
The API 4400 G series uses no transformers or choppers in the 
signal path for best noise immunity and freedom from AC arti-
facts in the output. The inputs are not isolated from each other 
and use the same signal common connection. The modules do 
features full 3-way (input, output, power supply) isolation. A 
wide bandwidth 1 millisecond response model is available for 
high-speed applications.
Common ranges as well as custom ranges are possible. 
Consult the factory for assistance with special ranges. 

LoopTracker 

API exclusive features include two LoopTracker LEDs (green for 
input, red for output) that vary in intensity with changes in the 
process input and output signals. These provide a quick visual 
picture of your process loop at all times and can greatly aid in 
saving time during initial startup and/or troubleshooting. 

Output Test 

An API exclusive feature includes the Functional Test Button 
to provide a fixed output (independent of the input) when held 
depressed. The output test level is adjustable from 0 to 100% 
of output span. 
The functional test button greatly aids in saving time during 
initial startup and/or troubleshooting.

Installation

The API 4400 G through API 4408 G plug into an industry stan-
dard 11-pin octal socket sold separately. Sockets API 011 and 
finger-safe API 011 FS allow either DIN rail or panel mounting.
The plug-in design, 3-way isolation, and robust electronics 
allows the module to be quickly hot-swapped without removing 
the power or I/O signals.

DC Input Ranges

Factory configured, please specify each input range 
 

Minimum Maximum 

Voltage: 

0-100 mVDC  0-10 VDC 

Bipolar voltage:  ±100 mVDC  ±10 VDC 
Current: 

0-1 mADC 

0-20 mADC, 4-20 mA

Popular ranges:  0-1 VDC, 0-5 VDC, 1-5 VDC, 0-10 VDC,  
 

±5 VDC, ±10 VDC, 0-20 mA, 4-20 mA

System voltages must not exceed socket voltage rating 
Inputs are converted to a percentage and then the math 
function is applied. Consult factory for mixed ranges, special 
ranges or non-standard functions.

Input Impedance

Voltage: 

100 k

 per volt nominal 

Current: 50 

 nominal

Input Voltage Burden (Current)

1.0 V

RMS

 maximum

Balance Between Inputs

Better than ±0.5% of span

LoopTracker

Variable brightness LEDs indicate I/O loop level and status

DC Output Range

Factory configured, please specify output range or consult fac-
tory. See table on other side for common ranges.
Voltage, 10 mA max.:  0-1 VDC  to 

0-10 VDC 

Bipolar voltage: 

±1 VDC  to 

±10 VDC 

Current: 

0-1 mADC  to  0-20 mADC

 

20 V compliance, 1000 

 at 20 mA

Output Calibration

Multi-turn zero and span potentiometers for output 
±15% of span adjustment range typical

Output Loop Power Supply

20 VDC nominal, regulated, 25 mADC, max. ripple <10 mV

RMS

Output Test

Sets output to test level when pressed 
Adjustable 0-100% of span

Output Ripple and Noise

Less than 10 mV

RMS

Linearity

Better than ±0.1% of span

Ambient Temperature Range and Stability

–10°C to +60°C operating ambient 

Better than ±0.02% of span per °C stability

Response Time

100 milliseconds typical, faster response times are available 

DF

 option: 1 millisecond response time

Isolation

2000 VRMS minimum 
Full isolation: power to input, power to output, input to output 
Individual inputs are single-ended (common ground)

Housing and Sockets

IP 40, requires installation in panel or enclosure 
API 011 or API 011 FS socket
Socket mounts to 35 mm DIN rail or can be surface mounted

Power

Standard: 

115 VAC ±10%, 50/60 Hz, 2.5 W max. 

P option: 

85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W  

A230 option:  230 VAC ±10%, 50/60 Hz, 2.5 W max. 
D option: 

9-30 VDC, 2.5 W typical

Hot Swappable 

Plug-In Design

Power options—add to end of model number
A230

 

230 VAC 

P

 

85-265 VAC or 60-300 VDC 

D

 

9-30 VDC

Options—add to end of model number
DF

 

Fast response, 1 millisecond nom. response time 

 

DF option will cause output noise levels greater  

 

than standard specifications. 

U

 

Conformal coating for moisture resistance

Accessories—order as separate line item
API 011

 

11-pin socket

API 011 FS

  11-pin finger-safe socket 

API CLP1

  Module hold-down spring for high vibration or  

 

mobile applications

Free Factory 

I/O Setup!

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

Made in USA

API 011 

300 V Rating

API 011 FS 

300 V Rating

API CLP1

1.75"

2.38"

Variable Brightness 

Input LED

Output Test Button

Output Test Adjust

Output Span

Output Zero
Variable Brightness 

Output LED

2.75"

Model

Function

Factory Configured Input

Output

Power

API 4400 G

 

(A + B + C + D) / 4

Specify 4 input ranges

Factory configured,  

specify output range

115 VAC

API 4401 G

 

(A + B + C) / 3

Specify 3 input ranges

115 VAC

API 4402 G

 

(A + B) / 2

Specify 2 input ranges

115 VAC

API 4403 G

 

(A + B + C – D) / 3

Specify 4 input ranges

115 VAC

API 4404 G

 

(A + B – C – D) / 2

Specify 4 input ranges

115 VAC

API 4405 G

 

A – B – C – D

Specify 4 input ranges

115 VAC

API 4406 G

 

(A + B – C) / 2

Specify 3 input ranges

115 VAC

API 4407 G

 

A – B – C

Specify 3 input ranges

115 VAC

API 4408 G

 

A – B

Specify 2 input ranges

115 VAC

Quick Link 

api-usa.com/4400

© 08-19

api-usa.com

1220 American Way Libertyville, IL 60048 
Phone: 

800-942-0315

 

Fax: 800-949-7502

A

BSOLUTE

 P

ROCESS

 I

NSTRUMENTS

Reviews: