DC to DC Transmitters, High Voltage Input, Isolated, Field Rangeable
API 4380 G HV3
Input:
0-1 V to ±200 VDC
Wide Ranging I/O
Output:
0-1 V to ±10 VDC or 0-2 mA to 4-20 mA
One Minute Setup!
O
One Minute Field Setup for Hundreds of I/O Ranges
O
External Switches & Tables for Range Selection
O
Full 2000 V Input/Output/Power Isolation
O
Input and Output LoopTracker
®
LEDs
O
Output Test Button
O
Built-In Loop Power Supply for Output
Q
Convert, Boost, Rescale Process Signals
Q
One Model Covers Multiple Applications
Q
Interface Process Signals with Panel Meters, PLCs,
Recorders, Data Acquisition, DCS, and SCADA
Systems
Applications
Description
The API 4380 G HV3 accepts a DC voltage input and provides
an optically isolated DC voltage or current output that is linearly
related to the input. This module is unique because it is field
rangeable for voltage inputs to ±200 VDC. Typical applications
include signal isolation and signal conversion.
The optical isolation between input and output makes this
module useful for ground loop elimination, common mode
signal rejection, and noise pickup reduction. The module
power supply is isolated, resulting in full 3-way (input, output,
power) isolation.
The API 4380 G HV3 input and output can be field-configured
via external rotary and slide switches. Common range settings
are on the module label. Most common ranges are built-in, and
can be selected from the table on the module, however virtually
unlimited combinations are possible. Consult the factory for
assistance with special ranges.
LoopTracker
API exclusive features include two LoopTracker LEDs (green for
input, red for output) that vary in intensity with changes in the
process input and output signals. These provide a quick visual
picture of your process loop at all times and can greatly aid in
saving time during initial startup and/or troubleshooting.
Output Test
An API exclusive feature includes the Functional Test Button
to provide a fixed output (independent of the input) when held
depressed. The test output level can be set via a potentiometer
from 0 to 100% of the output span.
The functional test button greatly aids in saving time during
initial startup and/or troubleshooting.
Installation
The API 4380 G HV3 plug into an industry standard 8-pin octal
socket sold separately. Sockets API 008 and finger-safe API
008 FS allow either DIN rail or panel mounting.
The plug-in design, 3-way isolation, and robust electronics
allows the module to be quickly hot-swapped without removing
the power or I/O signals.
DC Input Ranges
See table on other side for field selectable ranges
Consult factory for special ranges
System voltages must not exceed socket voltage rating
Voltage:
0-1 VDC
to
0-200 VDC
Bipolar voltage:
±1 VDC
to
±200 VDC
Input Impedance
Voltage: 1 M
W
minimum
Common Mode Rejection
120 dB minimum
LoopTracker
Variable brightness LEDs indicate I/O loop level and status
DC Output Ranges
See table on other side for field selectable ranges
Consult factory for special ranges
Voltage, 10 mA max.: 0-1 VDC to
0-10 VDC
Bipolar voltage:
±1 VDC to
±10 VDC
Current:
0-2 mADC to 0-20 mADC
20 V compliance, 1000
W
at 20 mA
Output Calibration
Multi-turn zero and span potentiometers for output
±15% of span adjustment range typical
Output Loop Power Supply
20 VDC nominal, regulated, 25 mADC, max. ripple <10 mV
RMS
Output Test
Sets output to test level when pressed
Adjustable 0-100% of span
Potentiometer factory set to approx. 50% of span
Output Ripple and Noise
Less than 10 mV
RMS
Linearity
Better than ±0.1% of span
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than ±0.02% of span per °C stability
Response Time
100 milliseconds typical
DF option: 30 milliseconds typical response time
Isolation
2000 V
RMS
minimum
Full isolation: power to input, power to output, input to output
Installation Environment
IP 40, requires installation in panel or enclosure
Use with API 008 or API 008 FS socket
Socket mounts to 35 mm DIN rail or can be surface mounted
UL 508C pollution degree 2 environments or better
Power
Standard:
115 VAC ±10%, 50/60 Hz, 2.5 W max.
P option:
85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W
A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max.
D option:
9-30 VDC, 2.5 W typical
Hot Swappable
Plug-In Design
Sourcing
mA Output
Sink or
Source
mA Input
Free Factory Setup
Specify I/O ranges if factory is to set switches
Options—add to end of model number
DF
30 millisecond response time, or consult factory
DF option will cause output noise levels greater than
standard specifications.
U
Conformal coating for moisture resistance
Accessories—order as separate line item
API 008
8-pin socket
API 008 FS
8-pin finger-safe socket
API CLP1
Module hold-down spring for high vibration or
mobile applications
Model
Input
Output
Power
API 4380 G HV3
Field configurable
Specify input range if factory is
to set switches
Field configurable
Specify output range if factory is
to set switches
115 VAC
API 4380 G HV3 A230
230 VAC
API 4380 G HV3 P
85-265 VAC or 60-300 VDC
API 4380 G HV3 D
9-30 VDC
2.75"
Free Factory
I/O Setup!
2.38"
1.75"
Variable Brightness
Input LED
Output Test Button
Output Test Adjust
Output Span
Output Zero
Variable Brightness
Output LED
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
Minute
Setup!
1
API 008
600 V Rating
API 008 FS
300 V Rating
API CLP1
Quick Link
api-usa.com/hvdc
E145968
115 VAC, 230 VAC models
with input up to ±150 VDC
www.mod-tronic.com | [email protected] | 1-800-794-5883