Input:
0-100 mV to 300 VDC, 0-1 mA to 0-5 ADC, 4-20 mADC
Output:
One 8 Amp DPDT Relay or Two 8 Amp SPDT Relays
O
Field Adjustable Setpoints
O
Plug-In Design for Fast Installation
O
Input LoopTracker
®
and Alarm Status LEDs
O
Alarm Test, Optional Reset Button
O
Sinking mA Input
Q
Process Limit Backup Alarm
Q
Tank Level Alarm
Q
Process Signal Over, Under, Out-of-Range Alarm
Model
Input
Standard Alarm Configuration
Power
API 1000 G
Factory ranged, specify
mV, V, or mA range
Order
5A
shunt option for 0-900
mADC to 0-5 ADC inputs
Single setpoint one DPDT relay
HI alarm, non-latching, normal acting
115 VAC
API 1000 G A230
230 VAC
API 1000 G P
85-265 VAC or 60-300 VDC
API 1000 G D
9-30 VDC
API 1020 G
Factory ranged, specify
mV, V, or mA range
Order
5A
shunt option for 0-900
mADC to 0-5 ADC inputs
2 setpoints, 2 SPDT relays
HI/LO alarms, non-latching, normal acting
115 VAC
API 1020 G A230
230 VAC
API 1020 G P
85-265 VAC or 60-300 VDC
API 1020 G D
9-30 VDC
DC Input Range
Factory configured, please specify input type and range
System voltages should not exceed socket voltage rating
Voltage:
0-100 mVDC to 0-300 VDC
Current:
0-1 mADC
to 0-900 mADC sinking
5A
option:
0-900 mADC to 0-5 ADC
Input Impedance and Burden
Voltage:
250 k
Ω
minimum
Current: 50
Ω
typical
Voltage burden: 1.25 VDC at 20 mA current input
Isolation and Input Protection
750 VAC
p
or 750 VDC common mode protection
Input isolated from power supply
LoopTracker
Variable brightness LED indicates input loop level and status
API 1000 G Relay Output
Two SPDT form C contact sets operating in unison as one
DPDT contact set
One setpoint, 12 turn potentiometer, 0-100% of span
Factory configured alarm type
Standard: HI alarm, non-latching, normal acting
Options: LO alarm, latching, reverse acting
API 1020 G Relay Output
Two independent SPDT form C contact sets
Two setpoints, two 12 turn potentiometers, 0-100% of span
Factory configured alarm action
Internal jumpers for HI/LO, LO/LO, HI/HI, LO/HI
Standard: HI/LO alarm, non-latching, normal acting
Options: LO/LO, HI/HI, LO/HI alarms, latching, reverse acting
Relay Contact Rating
8 A @ 240 VAC resistive load or 30 VDC resistive load
5 A @ 240 VAC inductive load (cos
f
= 0.4)
3.5 A @ 30 VDC inductive load (L/R = 7ms)
See graph on other side for relay load ratings
Caution: Do not exceed socket voltage rating
Use an RC snubber for inductive loads
Deadband
Alarm trip/reset window is symmetrical about the setpoint
API 1000 G
1.0 to 100% of span, 12 turn potentiometer.
API 1020 G
Fixed at 1% of span, standard
API 1020 G A
Adjustable deadbands, 1.0 to 100% of span,
1 turn potentiometer for each setpoint
Output Test/Reset Button
Toggles relay(s) to opposite state when pressed
Resets latching relay with
HT
option, available on 1000 G only
Response Time
70 milliseconds typical
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than 0.02% of span per °C stability
Housing and Sockets
IP 40, requires installation in panel or enclosure
API 011 or API 011 FS socket
Socket mounts to 35 mm DIN rail or can be surface mounted
Power
Standard:
115 VAC ±10%, 50/60 Hz, 2.5 W max.
P option:
85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W typ.
A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max.
D option:
9-30 VDC, 2.5 W typical
Options—add to end of model number
L
1000 G with LO trip. Alarm trips on decreasing signal.
HT
1000 G latching alarm with push button reset
HP
1000 G latching alarm with power-off reset.
Module power must be turned off to reset alarms
HH
1020 G with HI/HI trip. Alarms trip at their respective
trip points on increasing signal.
LL
1020 G with LO/LO trip. Alarms trip at their respective
trip points on decreasing signal.
A
1020 G with adjustable deadbands.
R
Reverse-acting alarms. Relay coils energized in an alarm
condition. No alarm condition with module power off.
5A
Shunt for 0-900 mADC to 0-5 ADC inputs. Includes
API 011 socket and 0.1
Ω
25W 1% shunt resistor.
U
Conformal coating for moisture resistance
Accessories—order as a separate line item
API 011
11-pin socket, DIN rail or surface mount
API 011 FS
11-pin finger safe socket, DIN rail or surface mount
API CLP1
Module hold-down spring for high vibration or
mobile applications
DC Input Alarm Trips, Factory Ranged
API 1000 G, API 1020 G
Applications
Description
The API 1000 G and API 1020 G are factory configured for
either a DC voltage or current input and provide alarm contact
outputs. Heavy duty relay contacts allow the module to directly
control high capacity loads.
The API 1000 G provides a single setpoint adjustment and
DPDT relay contacts. The alarm output can be factory config-
ured for HI or LO operation, non-latching or latching, normal
or reverse acting. Top-accessible potentiometers are used to
adjust the alarm setpoint and deadband.
The API 1020 G contains two independent setpoints with two
SPDT relay contact outputs. The alarm output can be factory
configured for HI/HI, HI/LO, LO/HI or LO/LO operation, normal
acting or reverse acting. Top-accessible potentiometers are
used to adjust each alarm setpoint. Deadband is fixed at 1% of
span. Adjustable deadbands are optional.
LoopTracker and Alarm Status LEDs
API exclusive features include a LoopTracker LED that varies in
intensity with changes in the process input signal.
A red/green bi-color alarm status LED (two on the API 1020
G) visually indicate alarm status. These LEDs provide a quick
visual picture of your process at all times.
Output Test/Unlatch
API’s exclusive functional test button can be used to verify the
alarm and system operation. The output test button greatly
aids in saving time during initial startup and/or troubleshooting.
The HT latching option provides the additional function of
unlatching the alarm when the reset button is pressed. The
alarm will reset if the alarm condition not longer exists.
API 1020 G
P 001 001
115 VAC
Your Required Input
Your Alarm Configuration
2.75"
Free Factory
I/O Setup!
Quick Link
api-usa.com/1000
API 1000 G
Variable Brightness Input LED
Bi-Color Relay LED
Deadband Adjustment
Setpoint Adjustment
Output Test Button
Reset w. HT Option
2.38"
1.75"
API 1020 G
A
Option Deadband Adjustments
2.38"
1.75"
Variable Brightness Input LED
Bi-Color Relay 2 LED
Bi-Color Relay 1 LED
Setpoint 2 Adjustment
Setpoint 1 Adjustment
Output Test Button
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
Hot Swappable
Plug-In Design
API 011
300 V Rating
API 011 FS
300 V Rating
API CLP1
© 08-18
api-usa.com
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
Fax: 800-949-7502
A
BSOLUTE
P
ROCESS
I
NSTRUMENTS