Absolute Process Instruments APD 4152 Quick Start Manual Download Page 1

Universal Thermistor to DC Isolated Transmitter, Field Configurable 

APD 4152

Input:

 

Thermistor, or Custom Sensor

Output:

 

0-1 V to 0-10 V,   ±5 V, ±10 V,   0-2 mA to 4-20 mA, Reverse Acting Optional 

 

O

One Model Covers All Common Thermistor Sensors

 

O

Easy Setup

No Computer or Software Needed

 

O

Zero and Span Output Calibration Buttons

 

O

Full 1200 V Isolation

 

O

Input LoopTracker

®

 LED, Output Test Function

 

O

Built-In Loop Power Supply for Sink/Source Output

 

Q

Convert/Isolate Thermistors for PLC Input, Control 
and/or Validation

 

Q

Interface Thermistors with Panel Meters, PLCs, 
Recorders, Data Acq., DCS, & SCADA Systems

Applications

Description

The APD 4152 accepts a thermistor temperature input and 
provides an optically isolated and linearized DC voltage or 
current output. 
The sensor type, temperature range and output range are field 
configurable. The input type is set with switches and its range 
is configured using front buttons, a multimeter and an input 
simulator. This provides a versatile solution that works with all 
commonly available thermistor sensors.
Microprocessor-based linearization uses 41 to 55 segments or 
up to a 14th order polynomial depending on the sensor type.
The input is sampled, digitally converted to a linearized tem-
perature signal and then passed through an optocoupler to the 
output stage. 
Full 3-way isolation (input, output, power) make this module 
useful for ground loop elimination, common mode signal rejec-
tion, and noise pickup reduction.
The low noise 18 bit analog output is isolated and can be set up 
for common voltage and milliamp output types. 

Output Sink/Source Versatility

Standard on the APD 4152 is a 20 VDC loop excitation supply 
for the milliamp output. The output can be selectively wired for 
sinking or sourcing allowing use with a powered or unpowered 
milliamp device. 

LoopTracker 

An API exclusive feature includes a green LoopTracker LED that 
varies in intensity with changes in the process input signal. 
It provides a quick visual picture of your process input at all 
times and can greatly aid in saving time during initial startup 
and troubleshooting. 

Output Test 

An API exclusive feature includes an output test switch to 
provide a fixed output (independent of the input) when pressed. 
The output test greatly aids in saving time during initial startup 
and/or troubleshooting. 
The test output level is adjustable from 0 to 100% of the 
output span.

Input Types, Field Selectable

Thermistors:  44004/44033 2.252 k

Ω

 at 25°C 

 

44005/44030 3.000 k

Ω

 at 25°C 

 

44007/44034 5.000 k

Ω

 at 25°C 

 

44006/44031 10.00 k

Ω

 at 25°C 

 

44008/44032 30.00 k

Ω

 at 25°C 

 

YSI 400 2.252 k

Ω

 at 25°C 

 

Spectrum 1003k 1 k

Ω

Custom: 

Provide sensor specifications, temperature  

 

curve data, and temperature range

LoopTracker

Variable brightness green LED indicates input level and status

Status LED

Yellow LED for setup and operational status

DC Output Ranges, Field Selectable

Voltage:  0-1 V, 0-2 V, 0-4 V, 0-5 V, 1-5 V,  
 

0-8 V, 0-10 V, 2-10 V, 

 

±5 VDC, ±10 VDC

Current:  0-2 mA, 0-4 mA, 0-8 mA,  
 

0-10 mA, 2-10 mA, 0-16 mA, 0-20 mA,  

 

4-20 mA

 

20 V compliance, 1000 

Ω

 at 20 mA

Reverse Acting Output, Factory Set

R

 option:  Reverse acting output  

 

increasing input = decreasing output signal 

Reverse acting models cannot be converted to direct acting

Output Calibration

Zero and span set by using up/down buttons, ±10% range

Output Loop Power Supply

20 VDC nom., regulated, 25 mADC, <10 mV

RMS

 max. ripple

May be selectively wired for sinking or sourcing mA output

Output Test

Front push button switch enables/disables test level output 
Adjustable 0-100% of span via up/down buttons

Output Resolution

18 bit

Output Ripple and Noise

Less than ±0.2% of span

Accuracy

±0.1°C accuracy and 0.001°C resolution

Ambient Temperature Range and Stability

–10°C to +60°C operating ambient 

Better than ±0.02% of span per °C stability

Response Time

300 milliseconds nominal 

Isolation

Full 3-way isolation: input, output, power, 1200 V

RMS

 min. 

600 VACp or 600 VDC common mode protection 
75 dB minimum common mode rejection 
Simultaneous 50 Hz and 60 Hz rejection

Housing and Connectors

IP 40, requires vertical installation on a 35 mm DIN rail inside 
a panel or enclosure 
For use in Pollution Degree 2 Environment 
Four 4-terminal removable connectors, 14 AWG max. wire size

Power

85-265 VAC, 50/60 Hz or 60-300 VDC, 3 W maximum 
D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 3 W maximum

Removable Plugs

Sink or Source  

mA Output

Setup and Status 

LED

Input LoopTracker 

LED

Zero and Span for 

Output

Universal 

Thermistor Input 

Adjustable Output 

Test Function

How to Order

Model

Description

Power

APD 4152

Thermistor input 

to DC output 

isolated  

transmitter

85-265 VAC, 50/60 Hz or 

60-300 VDC

APD 4152 D

9-30 VDC or 10-32 VAC

Options and Accessory

Universal 

Power

Note:

 An appropriate simulator and a multimeter are required 

for setup. We can set up the I/O ranges at no extra charge.

Models are field rangeable. For free setup specify the following.
Thermistor:  Sensor model/type, resistance
Custom: 

Complete sensor data over temperature range

Temperature:  Range in °F or °C
Output: 

Range and type (mV, V, mA)

Options—add to end of model number
NC5

 

5 point NIST traceable calibration certificate

NC11

 

11 point NIST traceable calibration certificate

U

 

Conformal coating for moisture resistance

R

 

Reverse acting output

Accessory—order as separate line item
API BP4

  Spare removable 4 terminal plug, black

Dimensions

Height includes connectors 
0.89" W x 4.62" H x 4.81" D (22.5 x 117 x 122 mm)

Quick Link: 

api-usa.com/apd4152

1  2  3  4

5  6  7  8

9 10 11 12

13 14 15 16

See Wiring 

Diagrams on 

Next Page

© 11-19

api-usa.com

1220 American Way Libertyville, IL 60048 
Phone: 

800-942-0315

 

Fax: 800-949-7502

A

A

BSOLUTE

BSOLUTE

 P

 P

ROCESS

ROCESS

 I

 I

NSTRUMENTS

NSTRUMENTS

Minute 

Setup!

1

Free Factory 

I/O Setup!

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

Made in USA

File E145968

85-265 VAC, 60-300 VDC 

model only

Applications Link 

api-usa.com/apps

Pb

Lead 

Free

Summary of Contents for APD 4152

Page 1: ...s Field Selectable Voltage 0 1 V 0 2 V 0 4 V 0 5 V 1 5 V 0 8 V 0 10 V 2 10 V 5 VDC 10 VDC Current 0 2 mA 0 4 mA 0 8 mA 0 10 mA 2 10 mA 0 16 mA 0 20 mA 4 20 mA 20 V compliance 1000 Ω at 20 mA Reverse Acting Output Factory Set R option Reverse acting output increasing input decreasing output signal Reverse acting models cannot be converted to direct acting Output Calibration Zero and span set by usi...

Page 2: ...sed 4 20 mA is 20 4 mA 1 Set switches A B and C from the table to set input type and range 2 Set switches D and E from the table to set the output range and set switch E V for voltage or I for current output For output ranges that fall between the listed ranges use the next highest setting The output can be trimmed using the zero and span buttons Electrical Connections See wiring diagrams at right...

Page 3: ...I 44005 44030 3 k 6285V 6283V 6284V 6287V 6282V 6289V 6286V 6281V 6288V 6280V 6283I 6287I 6282I 6289I 6286I 6281I 6288I 6280I 44007 44034 5 k 6385V 6383V 6384V 6387V 6382V 6389V 6386V 6381V 6388V 6380V 6383I 6387I 6382I 6389I 6386I 6381I 6388I 6380I 44006 44031 10 k 6485V 6483V 6484V 6487V 6482V 6489V 6486V 6481V 6488V 6480V 6483I 6487I 6482I 6489I 6486I 6481I 6488I 6480I 44008 44032 30 k 6585V 65...

Page 4: ...Libertyville IL 60048 Phone 800 942 0315 Fax 800 949 7502 A ABSOLUTE BSOLUTE P PROCESS ROCESS I INSTRUMENTS NSTRUMENTS Notes APD 4152 Date installed Model Serial number Location Input range Output range A B C D E Range Setup Record ...

Reviews: