background image

 

 
 
 
 
 
 
 

 

AX series 

User  Manual

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

STEP 

 

 

 

Simple Operation

 

 

Panel Weight 

Cooling System 

Fast Assembly

 

 

High Brightness Front Servicing

 

 

High Refre

Summary of Contents for AX Series

Page 1: ...AX series User Manual STEP Simple Operation Panel Weight Cooling System Fast Assembly High Brightness Front Servicing High Refre ...

Page 2: ...oduction 06 About AX series 06 Product Specifications 07 Basic Wiring Overview for Hanging Installation and Stacking Installation Locking System 09 Product Assembly 11 Hanging Bar Rigging Bar 15 Service and Maintenance 15 Accessories 19 Flight Cases 20 ...

Page 3: ...this manual carefully before installing powering up operating and maintenance of this product Follow safety instructions in this manual and on the product If you have any questions please seek help from Absen WARNING Please read the Safety Measures listed in this section carefully before installing switching on operating and maintenance of this product WARNING Safety Risk Might cause equipment dam...

Page 4: ...t a location near the product and should be clearly visible and easily reached This way in case of any failure the power can be promptly disconnected Before using this product check all electrical distribution equipment cables and all connected devices and make sure all meet current requirements Use appropriate power cords Please select the appropriate power cord according to the required power an...

Page 5: ...reen from within a 1 meter distance Do not use any optical devices that have converging functions to look at the screen to avoid burning the eyes Product Disposal Any component that has a recycling bin label can be recycled For more information on collecting reusing and recycling please contact the local or regional waste management unit Please contact us directly for detailed environmental perfor...

Page 6: ...etc as a medium for video broadcast information release and so on The product has a 1 58mm and 1 27mm pixel pitch and is high definition display for indoor rental use The AX series uses die cast aluminum structure and the cabinet design is modern slim and light The display has excellent flatness high quality cabinet and module finish and high structural strength The cabinet dimension is 610 X 343 ...

Page 7: ...Magnetic Locking system Locking system Locking system Power box Protection corner ...

Page 8: ...z 3840 Drive Mode 1 36 Picture Frame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 800 Horizontal Viewing Angle 160 Vertical Viewing Angle 140 Electrical Parameters AC Input Voltage V 100 240 AC Input Frequency Hz 50 60 Maximum AC Input Power W m2 860 Average AC Input Power W m2 285 Environmental Parameters Storage Tempe...

Page 9: ...ameters Color Processing Depth Bit 14 Grayscale 16384 Refresh Rate Hz 3840 Drive Mode 1 46 Picture Frame Frequency Hz 50 60 Signal Transmission Distance m UTP cable 100 m Single mode fiber 10 km Optical Parameters Brightness nit 600 Horizontal Viewing Angle 160 Vertical Viewing Angle 140 Electrical Parameters AC Input Voltage V 100 240 AC Input Frequency Hz 50 60 Maximum AC Input Power W m2 650 Av...

Page 10: ...0 Leasing Product Installation Cabinet Installation Method hanging stacking Maximum number of hoisted cabinets 25 2 Basic Wiring Overview for Hanging Installation and Stacking Installation Notes 6 panels high 12 panels high ...

Page 11: ...System 2 1 Standard Locking Auto Lock and Auto Eject systems Auto locking Vertical Lock System With Magnetic Auto connection For Fast and Easy 1 Man Installation With Ultimate Safty And Pixel Protection Auto ejection Side Lock System Enables Super Fast East And Convenient Disconnection Of Panels Take out the panel from the flight case Pressing the four corners push of the box Auto Retracting corne...

Page 12: ...er and outer curve lock systems Innovative integrated repositionable curve connection block system maintains the highest level of alignment accuracy in both flat of curve configuration Curve connection blocks are available to support any increment of curve 2 5 degree concave giving users unlimited design flexibility and control ...

Page 13: ...03 Product Assembly 3 1 Procedure Stacking ...

Page 14: ...Hanging 3 2 Hanging Installation Fix the Hanging Bar on the Truss Turn the adjustment screw to make the clamps close The hanging bar should be directly affixed to the truss ...

Page 15: ...Connect and assemble tiles 3 2 Stacking system ...

Page 16: ...3 2 hanging bar 0 61m hanging bar 1 22m hanging bar ...

Page 17: ...04 Service and Maintenance Module Front Maintenance 1 Take off the failure module ...

Page 18: ... tool to the module and press the maintenance tool switch before vacuum for 5 seconds Pull it vertically and pull the module off the panel Step 2 Unload the module safety rope and remove the failure module Easy Maintenance for Power Box ...

Page 19: ...Step1 Push the switch upwards and turn on the power box Step2 After removing 2 pcs screws remove the recevied card Step3 After removing 4 pcs screws remove the power supply 05 Accessories ...

Page 20: ...ion 1m Name Sending card Box Dimension W480 H45 D240mm Name Flight case Dimension 1036x664x576mm Max Capacity 8 in 1 Name Front Maintenance tool Name base stand Dimension 0 68m 1 22m Name Adjustable Beam Connector Different Dimension 0 9 1 3M Name ladder Dimension 0 686m 0 43m Name Outrigger Dimension 0 8m Name Clamp between the tile and the ladder 06 Flight case ...

Page 21: ...es are optimised to fit in vehicles for low cost transport Fully stackable to save space 8 in 1 design All rights reserved by Shenzhen Absen Optoelectronic Co Ltd Shenzhen Absen Optoelectronic Co Ltd reserves the rights to modify contents without any further notice ...

Page 22: ...Shenzhen Absen Optoelectronic Co Ltd 18 20F Building 3A Cloud Park Bantian Longgang District Shenzhen 518129 P R China T 86 755 89747399 E absen absen com W www absen com ...