background image

Absco Industries

Assembly Instruction Manual

ABSCO PREMIER SHED

MODEL: 30302GK

3.00mW x 3.00mD x 2.10mH

Model: 30302GK

20/08/18

1.20

1  

 

 

Download the Absco 
Sheds Assembly App 
for instructional videos 

MANU FA CT URED

IN A US TR ALIA

SNAPTiTE

Assemb ly

AU: 1800 029 701

N Z: 0800 466 444

[email protected]

www.abscosheds.com.au

When laying concrete slab, ensure there 
is a rebated edge 25mm deep around the 
perimeter. This will help water egress from 
the base of the shed.

For construction in non-cyclonic areas
Wind rating: N2 as per AS4055-2012

ABSCO INDUSTRIES

ASSEMBLY INSTRUCTION MANUAL

SHED MODEL: 23151GK 

21-11-2017  

      

CONCRETE SLAB

2360mm

1620mm

FRONT:   2.26m

SIDE:       1.52m

HEIGHT:  1.95m

We thank you for choosing an Australian made

shed. For further assistance please visit our detailed

instructional video library at

Http://www.abscosheds.com.au/watch-videos

At ABSCO Industries we are always looking to be

number ONE, so please let us know what you think

of our instructions. Feedback makes us better.

[email protected]

CONCRETE 

REBATED EDGE

BOTTOM CHANNEL

CONCRETE SLAB

75mm WIDE REBATE

100mm

WHEN LAYING YOUR CONCRETE

SLAB, ENSURE THERE IS A

REBATED EDGE 25mm DEEP

AROUND THE PERIMETER

THIS WILL HELP WATER EGRESS

FROM THE BASE OF THE SHED

Absco Industries

Premier Shed Model: 23151GK

PAGE 01

CONCR

ETE SLA

B

3100mm

3100

mm

Summary of Contents for 30302GK

Page 1: ...SSEMBLY INSTRUCTION MANUAL SHED MODEL 23151GK 21 11 2017 CONCRETE SLAB 2360mm 1620mm FRONT 2 26m SIDE 1 52m HEIGHT 1 95m We thank you for choosing an Australian made shed For further assistance please visit our detailed instructional video library at Http www abscosheds com au watch videos At ABSCO Industries we are always looking to be number ONE so please let us know what you think of our instru...

Page 2: ...or the shed must be level An uneven surface may result in misalignment of parts The shed shall be erected on top of a reinforced concrete slab and anchored down appropriately illustrated on FINAL CONSTRUCTION page TOOLS REQUIRED SAFETY NOTES Some parts may have sharp edges It is advisable to wear gloves when handling these items and safety glasses if drilling holes Sensible shoes are highly recomm...

Page 3: ... SHEET 1915mm X 773mm 36L 2 STEEL SHEET 1915mm X 773mm 36R 2 15A 2 PEAK BRACE COMPONENT DESCRIPTION PART No CHECK COMPONENT DESCRIPTION PART No CHECK QTY QTY STEEL SHEET 1785mm X 711mm 34A 2 STEEL SHEET 1725mm X 773mm A 1 STEEL SHEET 2045mm X 773mm 38R 2 STEEL SHEET 1546mm X 773mm 45A 8 STEEL SHEET 2045mm X 773mm 38L 2 STEEL SHEET 1725mm X 773mm B 1 97AL 1 RIDGE BEAM 1 L 1521mm 59 9 97AR RIDGE BEA...

Page 4: ...25mm 79A 1 CHANNEL L 1568mm 55AL 55CL 55BL 81BL 81AL 60AL 55CR 1 1 1 1 4 2 1 1 1 1 4 2 CHANNEL L 1496 5mm 58 9 CHANNEL L 1496 5mm 58 9 CHANNEL L 1496 5mm 58 9 CHANNEL L 1496 5mm 58 9 CHANNEL L 1496 5mm 58 9 CHANNEL L 1496 5mm 58 9 55BR 81BR 81AR 60AR 55AR CHANNEL L 1496 5mm 58 9 CHANNEL L 1496 5mm 58 9 CHANNEL L 1496 5mm 58 9 CHANNEL L 1496 5mm 58 9 CHANNEL L 1496 5mm 58 9 CHANNEL L 1496 5mm 58 9 ...

Page 5: ...UCTIONS FITTINGS PACKET 89C JAMB L 1725mm 1 89A JAMB L 1785mm 2 12A 2 DOOR STRAP L 165mm CSJ 10 CHANNEL JOINER L 200mm 7 9 DOOR PADBOLT HASP 2 3 SELF TAPPING SCREWS PACKET CONTAINING 220 1 DOOR PADBOLT 3 16 COUNTERSUNK SCREWS NUTS 12 3 16 ROUND HEAD BOLTS NYLOCK NUTS 8 3 2 x 8mm BLIND POP RIVETS 12 PSTKDBL DOUBLE DOOR FITTINGS PACK PACK12P SCREW PACK 12 PACK12P SCREW PACK 12 1 PHILLIPS DRIVER BIT ...

Page 6: ...he channel along the sheets until each end is neatly flush If you need to remove channels from the panels slide it off from the side Channel locks the shed panel into position without the need for screws FASTENING SYMBOLS Secure channel to sheeting by SNAPTiTE fastening method Join components together with one screw at this location only as some channels have extra holes that are not required for ...

Page 7: ... end of the channel where the JOIN text is marked Push down one side of the CSJ until you hear a click Step 3 Join the second channel to the CSJ by positioning the JOIN of the channel at the centre of the CSJ on an angle Push the CSJ into the channel until you hear a click Finished Channel The joined channels should now look like the picture with the CSJ positioned equally inside of the joined cha...

Page 8: ... channels may have holes in them You will need to redrill holes where CSJ joining channel covers them Join together 16 x channel sections using 8 x channel joiners Part CSJ 4x 81AR 4x 81AL 2x 60AR 2x 60AL 1x 55AR 1x 55AL 1x 55CR 1x 55CL 1x 55BR 1x 55BL 1x 81BR 1x 81BL 2993mm 81BL 55BL 55CL 55AL 60AL 81AL 81BR 55BR 55CR 55AR 60AR 81AR 4x 81A 2x 60A 1x 55A 1x 55C 1x 55B 1x 81B ...

Page 9: ... 50mm overlap of the ridge caps when the beams are in position Step 2 Use the ZARSP to connect at the centre of the two ridge beams Be sure it is pushed in fully Step 3 Turn over the ridge beam Measure 250mm from the middle along the centre of one ridge beam mark spacings of 50mm Fasten with a Tek screw at each marking Repeat to the other side of the ridge beam assembly TIP Predrilling each hole w...

Page 10: ...bly Instruction Manual ABSCO PREMIER SHED MODEL 30302GK 3 00mW x 3 00mD x 2 10mH Model 30302GK 20 08 18 1 20 10 PRE ASSEMBLY OF SPLICED RIDGE BEAM 1x 97AL 1x 97AR 1x 97A 2993mm Overall length ZARSP 225mm 97AL 97AR 16mm 16mm ...

Page 11: ...ruction Manual ABSCO PREMIER SHED MODEL 30302GK 3 00mW x 3 00mD x 2 10mH Model 30302GK 20 08 18 1 20 11 OVERVIEW OF ROOF COMPONENTS OVERVIEW OF ROOF COMPONENTS 87A 60A 14A 87A 81A 87A 87A 14A 81A 97A 45A 45A 45A 45A 45A 45A 45A 45A ...

Page 12: ...HED MODEL 30302GK 3 00mW x 3 00mD x 2 10mH Model 30302GK 20 08 18 1 20 12 OVERVIEW OF WALL COMPONENTS OVERVIEW OF WALL COMPONENTS 81A 84L 55B 84R 84L 15A 55A 30A 30A 31A 31A 81B 36L 38L 36R 34A 55C 84R 36R 34A 38R 81A 38R 38L 36L 79A 89A 89A 91A 90A 91A B 22A A ...

Page 13: ... Industries Assembly Instruction Manual ABSCO PREMIER SHED MODEL 30302GK 3 00mW x 3 00mD x 2 10mH Model 30302GK 20 08 18 1 20 13 REAR PANEL ASSEMBLY 1x required 30A 31A 31A 30A 55B 81B SNAPT TE i SNAPT TE i ...

Page 14: ...anual ABSCO PREMIER SHED MODEL 30302GK 3 00mW x 3 00mD x 2 10mH Model 30302GK 20 08 18 1 20 14 ROOF PANEL ASSEMBLY 2x required Fit 81A to edge of sheet with pre punched holes 45A 45A 45A 45A SNAPT TE i SNAPT TE i 87A 81A 87A 60A D D D D D D ...

Page 15: ...K 3 00mW x 3 00mD x 2 10mH Model 30302GK 20 08 18 1 20 15 SIDE PANEL ASSEMBLY 2x required INSIDE OF SHED Trim the tip of each sheet or bend out of the way to allow channels to fit hard up to the edge of the sheet 36L 38L 38R 36R 84R 81A 84L 15A SNAPT TE i SNAPT TE i SNAPT TE i ...

Page 16: ...O PREMIER SHED MODEL 30302GK 3 00mW x 3 00mD x 2 10mH Model 30302GK 20 08 18 1 20 16 FRONT PANEL ASSEMBLY 89A 89A 90A 79A SNAPT TE i SNAPT TE i SNAPT TE i SNAPT TE i 34A 5A 89A 90A 5A 89A 90A 5A 5A 79A 79A 5C 5C 89A 5 5 5 5 5 5 1x required 34A 55A 55C ...

Page 17: ...17 DOOR PANEL ASSEMBLY 58C 58C 58C 12A 58C 58A 58A A B 89C 58B A B SNAP T TE i SNAP T TE i SNAP T TE i SNAP T TE i Vertical door channels are installed in the opposite orientation compared to the horizontal door channels Four hole set for padbolt connection Short flange of channel Long flange of channel D D D D D D D D 1x required ...

Page 18: ...EMBLY Nuts and bolts may be used instead of pop rivets by drilling out hinge holes using a 4mm drill bit Both are supplied The two holes required to connect the padbolt hasp for each door have not been pre punched to allow for proper alignment position each hasp centrally over the padbolt shaft and drill 3mm holes and secure with screws 91A 91A A B ...

Page 19: ... The top channels of each panel are pre punched for attaching roof sheeting The base channels are not pre punched Side wall channels fit into the notched rear wall channels Pre punched holes in roof panel to this side for connection to front and rear walls Pre punched channel to match ridge beam holes Orient panel so channel 60A goes into ridge beam Channel 81A this end 97A D D D D D D D D D D D D...

Page 20: ...ODEL 30302GK 3 00mW x 3 00mD x 2 10mH Model 30302GK 20 08 18 1 20 20 Secure peak brace to ridge beam and roof panel with one screw at each end INSIDE VIEW OF FIXING Move the other roof panel into position and secure peak brace to ridge beam with one screw at each end ...

Page 21: ...to the wall sheet Drill a 10mm hole into the concrete Bolt and Nut M10 4 6 S Steel Angle 35 x 35 x 3 M10 Dynabolt Denotes hot dip galvanised finish Wall Sheet Slab 14A Bend the top and bottom flanges as shown then hook the bottom flanges under the top channel and screw top to the ridge beam with two screws ANCHORING OF SHED Location of 15 concrete anchors 250 250 1000 1000 1000 1000 250 360 360 36...

Page 22: ... the installation contractor Scaling of drawings shall not be undertaken 7 G Prior to commencing works on site the contractor shall verify the position of all services in the area to ensure that the construction does not interfere with any of those services 8 G During installation on site the shed structures shall be maintained in a stable condition with no part becoming overstressed or permanentl...

Page 23: ...levant provisions of AS1562 Steelwork 1 F The supporting slab foundation for the garden shed shall be of a minimum size indicated on the installation manual The top surface of the formed slab shall be level and free of any irregularities which would inhibit the installation of the shed 2 F The structural engineering design for the supporting slab foundation shall be undertaken by a suitably qualif...

Page 24: ...he benefits given by the warranty are in addition to your other rights and remedies under a law in relation to the goods or services to which the warranty relates The warranty applies to the exclusion of all other representations guarantees or warranties express or implied our goods come with guarantees that cannot be excluded under the Australian consumer law and is not transferable You are entit...

Page 25: ...lbarrows garden tools etc Storage items that might be adversely affected by any of the above conditions may require additional protection such as being sealed or covered by plastic sheets and or stacked above the concrete floor on timber slats Waterproof sealants may be used to offer further protection where required around joins and screw fixings as can rubber door seals and other products which ...