12
Assembly of the operator and the sliding arm DA149 to the closing side
- After installation, ensure that the arm and door are
properly adjusted.
- Mount a door stop to the door open position so that
wind will not drive the door against the wall, resulting
in damage.
- Tighten the holding screw.
Frame
depth
DA149
0-24
24-75
75-100
130
120
115
750
740
735
Frame
depth
H
/mm
Arm
distance
L
/mm
Minimum
door width
M
/mm
Hinge line
Mounting of the operator
M8x22 and washer
Y (mm) Length of extension piece
47
10 mm (DA150/01)
57
20 mm (DA150/02)
67
30 mm (DA150/01, DA150/02)
77
40 mm (DA150/02 2 pcs)
97
60 mm (DA150/06)
Y
297
Min. 37*
M
L
585
* From the mounting plate to the
mounting hole of the sliding rail,
without extension piece.
Mounting of the arm to the operator M8x30 and washer.
It is always recommended to use 10 mm extension piece.
All manuals and user guides at all-guides.com