REPLACING THE BATTERY

 

Note

Once the battery is disconnected, the loads are not 

protected from power outages. 

1. 

Use an insulated philip screwdriver to remove the four screws 
located   
at the base of the UPS.   

2. 

Remove the front panel and top cover. 

3. 

Disconnect the battery cable terminals before removing the 
battery from the UPS. 
Step1: Loosen the black cable from the negative (-) terminal. 
Step2: Loosen the red cable from thepositive (+) terminal.

 

4. 

Connect the battery cables to the terminals of thenew battery. 
Step1: Insert the black cable to the negative (-) terminal. 
Step2: Insert the red cable to thepositive (+) terminal. 

Note: Small sparks at the battery connectors are normal during connection. 

5. 

Slide the battery into the UPS. 

6. 

Close the front panel and fasten the four screws located at the base of the UPS. 

7. 

Dispose off the old battery properly at an appropriate recycling facility.

 

 
 
 

 

 

USER’S MANUAL 

800LS /1000LS

 

 

This manual contains important safety instructions. Please follow all instructions during installation. Read this manual thoroughly before unpacking, 
installing or operating. 

 
Caution: Risk of Electric Shock 

 

The UPS contains batteries.    The output outlets may be electrically live even when the UPS is disconnected from the AC mains. 

 

The UPS contains potentially hazardous voltages.    Do not open the units as there are no user serviceable parts.    All maintenance and servicing 
should be performed by qualified service personnel.   

 

Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage may exist between battery terminals and ground. Test 
before servicing and use insulated tools. 
 

NOTE:

The UPS is designed to be for use with computer loads only. 

Caution

Do not connect a laser printer to the UPS.     

A laser printer draws significantly more power than other types of equipment and may overload the UPS.

 

SETUP 

 

Inspection 

 

Inspect the UPS upon receipt. 
Notify the carrier and dealer if there 
is damage. The package is 
recyclable; save it for reuse or 
dispose of it properly. 
 

Inspect accessories: 

 

Power cable 1PCS 

USER MANUAL 1PCS 

 

 

Choose an installation location 
 

-  Avoid locations that are excessively humid, near water, 

near heat sources or in direct sunlight 

-  Allow 1inch (2.5cm) clearance on each side of the UPS. 

 

 

 

Connecting Equipment and Power to the UPS 

 
 
 
 
 
 
 
 
 
 
 

 

ConnectModem/ Phone / Network for Surge Protection (Optional) 

 
 
 
 

 

ConnectInterface Device 
 

 

 

Turn ON/OFF the UPS 
 

Turn on theUPS:Press the UPS 
On/OFF Switchfor approx. 3 
seconds, then the Buzzer sounds 
twice, the UPS will start-up.   
Turn off theUPS:Press the UPS 
On/OFF Switchfor approx. 3 
seconds, then the Buzzer 
soundstwice, the UPS will 
shutdown. 
 

Cold Start Function 

When the UPS is OFF and no utility input 
power is present, use the “Cold Start” feature 
to apply power to the loads from UPS‘s battery. 
Press the “ON/OFF” switch untilthe UPS 
beeps. 

Software Download and Installation 

Please follow steps below to download and install monitoring software: 
1. Go to the website http://www.ablerex.com.sg/downloads.html 
2. Depending on the computer OS, select Emily software (for Win 7&8 OS, select Emily2) and click download. 
3. Follow the on-screen instructions to install the software. 
4. When the computer restarts, the monitoring software automatically search and connects to the UPS. 

 

FRONT PANEL EXPLANATIONS

 

REAR PANEL EXPLANATIONS

 

800LS/1000LS–LED FRONT   

PANEL (STANDARD)

 

Symbol

 

LED 
Color

 

Description/function 

800LS/1000LS REAR PANEL

 

Symbol

 

Description

 

 

 

N/A

 

Turn-on/Turn-off 
Switch

 

 

AC Input Outlet 

 

Green

 

Lit: Line mode 
Dim: Abnormal input 
voltage and 
frequency   

Fuse 

Output Connector: 

4x Thailand Outlets 

 

Yellow

 

Lit: Battery mode 
Flashing: Battery 
Low

 

USB (Standard) 

 

Red

 

Lit: System 
malfunction   
or abnormal

 

Step1: Connect the UPS to the 
AC mains. 
Step2: Connect the equipment to 
the UPS output outlets. 
Step3: Switch on the AC Mains, 
follow by the UPS then the 
equipment last. 
*Plug the UPS into the AC Mains 
to charge for 8 hours before 
using the UPS. 

-  For modem/phone line protection, 

connect equipment to the RJ11 
port using RJ11 cable. 

-  For surge protection, connect 

equipment to the RJ45 port using 
Ethernet/RJ45 cable. 

 

The UPS is equipped with 
two interface ports: a USB 
port (Standard) and a 9-pin 
RS232 port (Optional) 
allowing advanced 
communication network 
between the UPS and a 
computer (network).

 

Reviews: