| Error resolution and maintenance –
Taking the Wallbox eMH2 out of operation
50
Taking the Wallbox eMH2 out of operation
In case of severe malfunctions or damage to the device, you must take the Wallbox eMH2 out of operation. To do so,
proceed as follows:
1
Open the housing cover of the wallbox with the hous-
ing cover key and put it aside.
2
Open the access flap of the internal electronic compo-
nents cover.
3
Flip the pivot lever of the internal RCCB to the
0
posi-
tion.
y
Also flip the pivot lever of the internal MCB to
position
0
.
4
Close the access flap, hook the housing cover onto
the upper edge of the housing base and lock it using
the housing cover key.
5
Open your domestic power distribution box, discon-
nect the power supply cable from the electricity grid
via the MCB and close the distribution box.
The Wallbox eMH2 is no longer connected to the electricity grid and can be removed by a qualified specialist electri-
cal contractor if required.
DANGER!
Dangerous electrical currents
Always measure the voltage between the phases and the neutral conductor of the power supply cable before you
start dismantling the wallbox.