| Installation –
Requirements for the installation site
14
Installation
When installing the POLEMHx, various specifications regarding the location and the connection technology must be
met in order to ensure safe operation.
Requirements for the installation site
The POLEMHx was developed for outdoor use. To ensure proper installation, you as the operator must adhere to the
following specifications regarding the location and positioning.
Be sure to observe all local regulations for electrical installations, fire prevention and accident prevention.
All guidelines for the installation of low-voltage systems in accordance with IEC 60364-1 and IEC 60364-5-52
apply.
The installation surface must have sufficient strength to withstand the mechanical loads. It is therefore strongly
recommended not to install the POLEMHx directly on asphalt or a concrete floor, but to use a concrete foundation
such as the ABL EMH9999 with suitable specifications (concrete C20/25 in accordance with EN 206-1:2013).
A sufficiently dimensioned supply cable for the power supply of the respective wallbox must be provided at
the installation location. The supply cable must be laid so that it lines up with the pipe opening in the concrete
foundation and in the ground. If necessary, the supply cable must be protected against mechanical influences (by
a suitable hose or pipe) in the area in front of the foundation.
Suitable collision protection must be provided on site to provide the vehicle with mechanical protection from
possible collisions with the POLEMHx.
The minimum distance between the vehicle and the POLEMHx should be not less than 50 cm and not more than
150 cm.
Select the installation location so that the charging cable from the wallbox easily reaches the charging socket on
the vehicle: the cable must not under any circumstances be strained when connected to the vehicle.
For the safe operation of your mounting pole, minimum distances to other technical installations must be ob-
served: you can obtain further information from your electrical contractor or distributor.
The POLEMHx should not be installed in high-traffic areas or along thoroughfares.
The POLEMHx is designed in principle for operation at high ambient temperatures. However, it is important to
ensure that the maximum permissible operating temperature is not exceeded due to external influences such as
direct sunlight or similar.
Specifications for the mechanical installation of the POLEMHx
The entire installation of the POLEMHx should always be carried out by qualified personnel. at least two people are
required for the mechanical installation.
For mechanical installation of the POLEMHx, you will need the following components:
Triangular key for unlocking the
housing door (included with the
POLEMHx)
EMH9999 concrete foundation
for installing the POLEMH1/2/3
ISO 4017 hexagon screw,
M12×25, 4 pcs
(included with the EMH9999)