INSTALLINg ThE ChARgINg pOLE
19
4. Insert the power supply through the central opening in the plinth and position the
four screw holes in the base plate of the plinth above the drill holes.
5. Insert the bolt anchors with washers into the drill holes and tighten them using the
torque wrench.
CAUTION!
Ensure that the supply cable is non-live and protrudes sufficiently
(>
50
cm) from the high temperature plastic tube inside the foundation.
Mechanical installation of the charging pole on the plinth
At least two persons are required for the next steps in the installation of the charging
pole. You will also need the following components:
• Fork wrench or equivalent for M8 bolts, size 13/14 mm (not included)
• Spirit level if required (not included)
Proceed as follows:
1. Open the housing cover of the charging pole by unlocking the flip out handle on left
side of the
eMC2
using the temporary key included.
2. Bring the charging pole into position above the installed plinth. Insert the power
supply into the cable opening in the base of the charging pole.
3. Position the charging pole on the plinth so that the screw holes in the base plate
of the charging pole are directly above the openings in the top plate of the plinth.
4. Stick the included sealing tape across the upper rim of the plinth, exactly between
the screw openings in the front part of the pole.
5. Apply the sealing profile included and position it so that the screw holes are di-
rectly above the openings in the base plate of the charging pole and the openings
in the top plate of the plinth.
6. Using the fork wrench and the four M8 x 20 hexagonal head bolts included, fix the
sealing profile hand-tight to the charging pole and the plinth.
This step concludes mechanical installation of the charging pole. However, it is recom-
mended to use this opportunity to install a commercially available profile cylinder lock
in the flip out handle of the
eMC2
: Installation will be described in the instructions for
the cylinder lock, but please use the two M4 x 16 countersunk head bolts included to
secure the lock in the flip out handle.
PLEASE NOTE:
To dehumidify the interior space of the
eMC2
, we recommend to fill the
entire plinth area with a granulated desiccant: This serves to minimize
the unwanted effects of condensation and water seepage.