Summary of Contents for eMH1 Basic

Page 1: ...CHARGE YOUR FUTURE With ABL Charging Stations VERSION 563 2015 07 1608 14 eMH1 eMH1 Basic with cable EVSE 563 model Instruction Manual DE...

Page 2: ...1027 Lauf Pegnitz Germany Web www abl sursum com Mail info abl sursum com Contact Distribution Phone 49 0 9123 188 0 Fax 49 0 9123 188 188 Internet www abl sursum com Mail sales abl sursum com Contact...

Page 3: ...cking 7 Available accessories 7 Installation and power supply connection 9 Prerequisites for the mounting site and installation 9 Preparation and mechanical installation 10 Electrical installation of...

Page 4: ...the device out of operation 22 Appendix 23 Specifications 23 Standards directives 23 Trademarks 25 CE certification and compliance declaration 25 Warranty and guarantee provisions 25 Disposal advice 2...

Page 5: ...ith this symbol must NOT be carried out UNDER ANY CIRCUMSTANCES CAUTION Sections marked with this symbol draw attention to further hazards that may lead to damage to the station itself or to other ele...

Page 6: ...ions contained in this manual and printed on the device may lead to electric shock fire and or severe injury The device may only be operated in technically sound condition Malfunctions that af fect th...

Page 7: ...ce comply with the parameters of your local electricity grid and that the rated output is not exceeded during charging operations At all times comply with local safety regulations for the country in w...

Page 8: ...ts waxes or solvents such as cleaning fluid or paint thinner because they can dull the displays on the device The charging station MUST NEVER be cleaned using a pressure cleaner or similar implement C...

Page 9: ...like to find out more about available accessories and the remaining ABL SURSUM product range please visit our website at www abl sursum com Product description Your eMH1 charging station allows you t...

Page 10: ...able housing cover shield near the hinge Please open the cover shield before taking the device into operation and check the compli ance plate to ensure that the model variant you have installed is the...

Page 11: ...locking the housing cover shield Drilling template 1 Template for drilling the holes for wall mounting Should one or more components be missing after unpacking please contact your lo cal distributor i...

Page 12: ...an order CAUTION Please note that the do it yourself installation of accessory components is not permitted Please contact a qualified contractor or arrange installa tion with your local distributor Pl...

Page 13: ...conditions especially outdoors In selecting the mounting site you must consider the following points For the safe operation of your charging station minimum distances to other tech nical installations...

Page 14: ...ion is required Outdoors the charging station should only be installed in covered locations that provide sufficient protection from rainwater Installation in a garage or carport is recommended as long...

Page 15: ...d not included CAUTION Check the measurements on the drilling template with a calibrated mea suring tape BEFORE you mark the drill holes using the template and then drill them Drilling the mounting ho...

Page 16: ...it 2 Fix the two lower mounting points using the other two screws 5 x 60 mm screw head 8 mm 3 Tighten the two lower screws so that the rear part of the housing is held in place without being deformed...

Page 17: ...e supply cable for the 3 phase EVSE 563 is connected as follows Designation Wire colors Connection coding Current carrying conductor phase 1 BROWN L1 Current carrying conductor phase 2 BLACK L2 Curren...

Page 18: ...witch the MCB in your domestic power distribution box back on Note We recommend that you take your charging station into operation in the presence of a qualified installer He or she will be able to as...

Page 19: ...he EVSE 563 model variant has a switch that you can flick to interrupt the Control Pilot signal to the charging socket and thereby prevent detection of the electric vehicle To prevent unauthorized acc...

Page 20: ...ocedures the charging connector must always be properly stored and thereby secured in its compartment Never leave the connector lying out in the open or plugged into the vehicle after charging is comp...

Page 21: ...erive your personal charging routine accordingly Please follow the following steps to charge your vehicle 1 Park your vehicle so that the charging socket can be easily reached with the charg ing conne...

Page 22: ...s completed when the blue LED is flashing Note Should there have been a malfunction during or after the charging pro cedure this will be shown by the indicator LEDs The following chapter describes how...

Page 23: ...e front cover shield show the current op erating status of the eMH1 charging station To indicate certain operating states the LEDs may be illuminated continuous ON flash be extinguished continuous OFF...

Page 24: ...d shows them us ing the indicator LEDs To represent certain errors the indicator LEDs will flash in a specific repeating pat tern The following error codes are displayed LED SEQUENCE FLASHING ERROR DE...

Page 25: ...ulty they must be replaced In this case please con tact your local distributor The electric vehicle is not recognized The charging cable is not properly plugged into the vehicle Remove the recharge pl...

Page 26: ...ion 0 Now the EVSE 563 is completely free of electricity and may be demounted if required WARNING The electrical de installation of the EVSE 563 must always be carried out by a qualified electrical co...

Page 27: ...to 6 mm2 Operating temperature 25 C to 50 C Storage temperature 30 C to 85 C Relative humidity 5 to 95 no condensation Class of protection I Degree of protection housing IP54 Overvoltage category III...

Page 28: ...ents E DIN EN 61851 22 2011 04 Conductive charging systems for electric vehicles Part 22 AC charging station for electric vehicles HD 60364 7 722 2012 Low voltage installations Part 7 722 Power supply...

Page 29: ...ce declarations can be obtained from ABL SURSUM Bayerische Elektrozubeh r GmbH Co KG on request and are available at www abl sursum com for download Warranty and guarantee provisions ABL SURSUM provid...

Page 30: ...will attempt to restore the proper functioning of the product The customer will be respon sible for covering any arising transport costs However the manufacturer further rejects any damage claims tha...

Page 31: ...ting diode MCB Miniature Circuit Breaker Residual current circuit breaker OCPP Open Charge Point Protocol Communication protocol between charging sta tion and service providers platform dependent PHEV...

Page 32: ...mounting holes yourself This is described in detail in section Installa tion and power supply connection on page 9 The following instructions which you must check in advance and may need to discuss wi...

Page 33: ...per installation e g by submitting the relevant invoices must be furnished on request before guarantee and warranty provisions come into effect Intellectual Property Copyright Copyright 2015 Version 1...

Page 34: ...he Elektrozubeh r GmbH Co KG Ottensooser Stra e 22 91207 Lauf Pegnitz Germany PO Box 10 02 47 91192 Lauf Pegnitz Germany info abl sursum com www abl sursum com Phone 49 0 9123 188 0 Fax 49 0 9123 188...