
26
Locking/Unlocking the Settings Lock
In order to protect channels/codes from being erased by accident when new codes are
programmed it is possible to lock each level separately. All levels are unlocked on delivery.
A locked level is indicated by a beep
when you try to program it.
Do as follows to lock/unlock the Settings Lock:
1. Press
P
and
---
at the same time. The indication lamp for the
Level
-button and the
current level are now lit.
2. Change to the level to be locked/unlocked by pressing
---
.
3. Press button
3
to lock or button
4
to unlock.
The indication lamp for the levels is automatically moved to the next level, which thereby
can be locked/unlocked immediately.
4. Press
---
2sec
for approximately 2 seconds until the indication lamp for the
Level
-button
flashes green and goes out.
Locking/Unlocking the Settings Lock
Press
P
+
---
,
choose level with
---
,
then press your desired option
3
or
4
then
---
2sec
.
3
= Lock.
4
= Unlock.
Default setting: Unlocked
Opening/Closing a Level
Your Control 18 has five different levels, which means that each button can have five
different functions. You can select the number of levels that are open and hence, how many
functions each button should have. You should close levels that are not to be used.
1. Press
P
and
---
at the same time. The indication lamp for the
Level
-button and the
current level are now lit.
2. Press
---
a number of times until the level to be opened or closed is reached.
3. Press
1
to open or
2
to close the chosen level.
The level indication lamp is automatically moved to the next level, which thereby directly
can be opened or closed.
4. Press
---
2sec
for approximately 2 seconds until the indication lamp for the
Level
-button
flashes green and goes out.
You can also open all levels at the same time, then press
A
.
Opening/Closing a Level
Press
P
+
---
,
choose level with
---
, then press the desired option
1
or
2
,
then
---
2sec
.
1
= Open.
2
= Close.
Default setting: Level 2 open
Summary of Contents for Gewa Control 18
Page 59: ...59...
Page 60: ...60 425718 1_Manual Gewa Control 18_SE GB NO_RevH docx Feb 2017...