Abilia Gewa Andromeda 419881 User Manual Download Page 4

2. Product Overview 

Andromeda Socket consists of the following parts: 
 
 
 
 
 
 
 
 
 
 
 
 

 

419881 Andromeda Socket UK 

 

1. 230V socket. For connection of  

    the device to be controlled. 

4. 

On/Off

 button. For programming and to 

    manually turn On/Off the power. 

2. Detector eye. Receives IR signal. 

5. 3.5 mm jack. For connecting an external 

    control switch. 

3. Indication light. 

 

 

3. Connection 

1.  Make sure that the device to be connected, that has its own power switch is set to “on”. This is 

easiest done by connecting to a wall socket and ensure that the device is on (for example a lamp 

should be lit). 

2.  Connect the Andromeda Socket to a wall socket. 
3.  Connect the device to be controlled to the socket on the relay unit (1). 
4.  Make sure that the device gets power by pressing the 

On/Off

 button (4). 

5.  If IR is used, keep in mind that the range will be reduced if the detector eye (2) is covered or 

hidden in some way, for example by curtains or furniture. 

6.  Program the relay unit by following the instructions in the next chapter. 

 

The Andromeda Socket comes factory set with GewaLink channel 16 and bistable function. The 

relay unit does not need to be programmed if it is the function and channel to be used on the IR 

transmitter. 

 

 

Summary of Contents for Gewa Andromeda 419881

Page 1: ...Andromeda Socket User manual Art Nr 419881 EN UK 1 0...

Page 2: ...smitter 6 4 3 Control with control switch 7 5 Resetting to default setting 8 6 Cleaning 8 7 Storage and disposal 8 7 1 Storage 8 7 2 Disposal 8 8 Technical data 9 8 1 Environment 9 8 2 Technical data...

Page 3: ...nd therefore can be used together with all of these products including Gewa IR transmitter and Z Wave transmitter The Andromeda Socket comes factory set with GewaLink channel 16 and bistable function...

Page 4: ...d ensure that the device is on for example a lamp should be lit 2 Connect the Andromeda Socket to a wall socket 3 Connect the device to be controlled to the socket on the relay unit 1 4 Make sure that...

Page 5: ...button on the IR transmitter until the indication light on the relay unit flashes and the relay have clicked 3 times 2 Check the function by pressing the selected button on the IR transmitter 4 1 2 K...

Page 6: ...ons provided by the controller manufacturer 2 Press the On Off button on Andromeda Socket three times within 1 5 seconds Reset Reset 1 Press and hold the On Off button on Andromeda Socket for approx 6...

Page 7: ...ndication light on the relay unit flashes and the relay have clicked 3 times 3 Check the function by pressing the control switch 4 3 2 Keep turned on monostable function Example To practice cause and...

Page 8: ...tion Z Wave network functions for more info 6 Cleaning The Andromeda Socket can be cleaned with a damp cotton wool pad with surgical spirit Chlorhexidine ethyl alcohol or isopropanol It can also be cl...

Page 9: ...ower consumption 2 0 W Maximum relay load 2990 VA 13 A resistive load Programming channels GewaLink channels 0 127 channel 62 has no function and 4096 code Frequency Z Wave 868 42 MHz Input control sw...

Page 10: ...ed or might lead to either of these situations The death of a patient user or other person The temporary or permanent serious deterioration of a patient s user s or other person s state of health A se...

Page 11: ...se Norway Abilia AS Tevlingveien 23 1081 Oslo Norway Phone 47 23 28 94 00 support abilia no www abilia no United Kingdom Abilia UK Ltd Unit12 Buckingway Business Park Swavesey Cambridge CB24 4AE Unit...

Page 12: ...12 Abilia AB R sundav gen 6 Solna Sweden Phone 46 0 8 594 694 00 info abilia uk www abilia uk 419880 81_User manual_Andromeda Socket_EN UK_March 2021...

Reviews: