ABICOR xFUME AF500 Operating Instructions Manual Download Page 12

EN 

-

 12

6 Operation

xFUME

®

 ABIROB

®

 AF500

6 Operation

6.1 Carrying out the welding process

1

Open the shielding gas cylinder.

2

Switch on the power source.

7 Decommissioning

1

Stop the welding process.

2

Wait until the shielding gas post-flow time has passed.

3

Switch off the power source.

4

Close the shielding gas cylinder valve.

8 Maintenance and cleaning

WARNING

Shortness of breath and poisoning caused by inhaling phosgene gas

When welding workpieces that have been degreased with chlorinated solvents, phosgene gas is formed. 
It can damage the respiratory tract when inhaled.
► Do not inhale fumes and vapors.
► Check and wear your personal protective equipment. 
► Ensure a sufficient supply of fresh air.
► Rinse the workpieces with clean water prior to welding.
► Do not place degreasing baths containing chlorine in the vicinity of the welding area.

WARNING

Risk of burns from sparks

During welding activities, sparks, glowing workpieces or hot slag can produce flames. This may result in 
serious burns.
► Check the work area for flashpoints.
► Check and wear your personal protective equipment. 
► Provide appropriate fire extinguishing equipment in the workplace.
► Allow workpieces to cool down after welding.
► Prior to performing welding work, properly fasten the ground clamp to the workpiece or welding 

table.

WARNING

Risk of arc eye

The arc produced by welding can damage the eyes.
► Check and wear your personal protective equipment (eye protection).

CAUTION

Risk of injury due to unexpected start

If power is supplied during maintenance, cleaning or disassembly, parts can start running unexpectedly 
and lead to injuries.
► Switch off the device.
► Close all supply lines.
► Disconnect the electrical power supply.

Summary of Contents for xFUME AF500

Page 1: ...T E C H N O L O G Y F O R T H E W E L D E R S W O R L D www binzel abicor com EN Operating instructions xFUME ABIROB AF500 EN Welding torch system...

Page 2: ...3 1 Emergency information EN 6 4 Product Description EN 6 4 1 Setup and functional description EN 7 4 2 Technical Data EN 8 5 Putting into operation EN 9 5 1 Setting up the torch neck EN 10 5 2 Settin...

Page 3: ...ing The device can be used to extract welding fumes that contain CMR substances and to extract welding fumes that do not contain CMR substances When extracting welding fumes that contain CMR substance...

Page 4: ...o based on their special training knowledge experience and due to their knowledge of the relevant standards are able to assess the tasks assigned to them and identify possible dangers Keep the work ar...

Page 5: ...Close the air regulator immediately afterwards The air regulator must be closed to ensure efficient capture of fumes Observe the instructions on the adapter label for connecting components When weldi...

Page 6: ...ackaged it is not possible to fully rule out the risk of transport damage Goods in inspection Check for order completeness by checking the delivery note Check the delivered goods for damage visual ins...

Page 7: ...MAG The standard torch neck types are available in the geometries straight 22 and 45 bends The uniform interface at the connection module makes all torch necks compatible with one another The connect...

Page 8: ...eneral torch data according to EN 60 974 7 xFUME ABIROB AF500 Type of voltage DC Polarity of the wire electrode for DC Usually positive Wire types Commercially available round wires Type of use Automa...

Page 9: ...7 145 6 mm 45 Contact Sales Contact Sales Contact Sales Contact Sales 15 75 400 mm Fig 1 Torch neck geometry Fig 2 Torch neck diameter A 26 5 mm B 18 mm Y2 X1 X2 Y1 cx A B CAUTION Risk of injury due t...

Page 10: ...eaching the stop 7 Screw the suction nozzle C into the fume tube E hand tight 8 Screw the gas nozzle A onto the tip adapter D hand tight 5 2 Setting up the cable assembly Select the correct wire type...

Page 11: ...ent the shielding gas supply from becoming clogged by impurities briefly open the cylinder valve before connecting the cylinder This will expel any impurities that may be present 2 Make all shielding...

Page 12: ...to welding Do not place degreasing baths containing chlorine in the vicinity of the welding area WARNING Risk of burns from sparks During welding activities sparks glowing workpieces or hot slag can...

Page 13: ...e the old liner E with a new one and insert the stripped side into the central connector B 5 Place the retaining sleeve A inverted by 180 onto the new liner E side without thread WARNING Electric shoc...

Page 14: ...amage to the device The product warranty will be rendered invalid if work is carried out on the product by unauthorized persons Consult the documentation for the welding components Tab 8 Troubleshooti...

Page 15: ...eets specified by the manufacturer of the consumables The disposal of dust collecting bags and disposal bags is subject to special waste regulations The dust must not enter sewage systems or be dispos...

Page 16: ...O L O G Y F O R T H E W E L D E R S W O R L D ABICOR BINEZL USA Inc 650 Medimmune Ct 110 Frederick MD 21703 T 301 846 4196 F 301 846 4497 customerservice abicorusa com www binzel abicor com INT 9059 2...

Reviews: