3 Instructions
SR/ABITIG
®
/ABITIG
®
GRIP
*According to EN 60 974-7 the value for alternating current (AC) must be
given at 70% of the tested direct current value (DC).
All data refer to 4m hose assemblies. For any further information regarding the
available hose assembly designs and performance data, please refer to the
order documentation.
3 Instructions
Observe the enclosed document Safety Instructions.
3.1 Classification
The warning signs used in the operating instructions are divided into four
different levels and are shown prior to specific work steps. Arranged in
descending order of importance, they have the following meaning:
Type
Type of
cooling
Load
ED
Electrode
Gas
flow
Cooling Torch
inlet
pressure
DC
AC*
Max.
supply temp.
Min.
flow
min.
max.
A
A
%
mm
l/min
°C
l/min
bar
bar
SR/ABITIG
®
/ABITIG
®
GRIP
24 G
air
110
80
35
0.5-1.6
5-12
24 W
liquid
140
100
100 0.5-2.4
7-15
50
0.7
2.5
3.5
ABITIG
®
12-1
liquid
400
280
100 1.6-4,0
7-20
50
0.8
2.5
3.5
18 SC
liquid
400
280
100 0.5-4,8
7-20
50
0.8
2.5
3.5
SR/ABITIG
®
/ABITIG
®
GRIP
9
air
110
80
35
0.5-1.6
5-12
17
air
140
100
35
0.5-2.4
7-15
26
air
180
130
35
0.5-4,0
7-18
18
liquid
320
230
100 0.5-4,0
7-20
50
0.8
2.5
3.5
20
liquid
240
170
100 0,5-6,4
8-22
50
0,7
2,5
3,5
SR (handle tube)
20
liquid
220
150
100 0,5-6,4
8-22
50
0,7
2,5
3,5
Tab. 4
Product-specific torch data (EN 60 974-7)
Liquid-cooled torches
min. 800 W
Tab. 5
Required cooling unit capacity