EN - 4
BAL.0140 • 2018-10-15
3 Product description
PP Plus 36D/240D/401D
2.3 Emergency information
In case of emergency, immediately interrupt the following supplies:
• Electrical power supply
• Coolant supply
• Compressed air supply
• Gas supply
• Further measures can be found in the "Power source" operating instructions or in the
documentation of further peripheral devices.
3 Product description
3.1 Technical Data
NOTICE
Describes the risk of impairing work results or potential material damage to the equipment.
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert or modify the device to enhance its performance without authorization.
• The device must only be used by qualified personnel (in Germany, see TRBS 1203).
Ambient temperature of welding
- 10 °C to + 40 °C
Transport and storage
- 25 °C to + 55 °C
Relative humidity
up to 90 % at 20 °C
Tab. 1
General Data
Type of voltage
DC direct voltage
Polarity of the electrode
Usually positive
Wire types
commercially available round wires
Type of use
manual
Voltage rating
113 V peak value
Protection type of the machine-side connections
IP2X , IP3X (EN 60 529)
Shielding gas (DIN EN ISO 14175)
CO
2
and mixed gas M21
Control device in torch handle
1 A AC / 250 V AC
Tab. 2
General torch data according to EN 60 974-7