EN - 34
10 Job mode (MFS-V3 only)
MFS service software
10.3 Job file editor settings (MFS-V3 only)
Description
Screenshot
Max. hot wire current [A] power source
The power source receives an analog target
value (0…10 VDC) for the hot wire current from
the eBOX.
This screen is used to set the maximum hot wire
current for the power source used.
That is, 0…10 VDC on the power source’s
analog input then equates to a hot wire current
of 0... max. A.
Target value for the hot wire current variable via bus or fixed in job
If the hot wire current should be saved in the
job, the value [A] for the hot wire current is
entered.
If the hot wire current in this job is variably
specified via a bus, the ‘Hot Wire from Bus’
field is selected.
If the wire speed should be saved in the job,
the value [m/min] for the wire speed is entered.
If the wire speed in this job is variably specified
via a bus, the ‘Wire Speed from Bus’ field is
selected.