9.16 Service interval settings (MFS-V3 only)
NOTICE
• An active connection to the eBOX is required for these settings.
9.6 Testing the connection on page EN-18
Description
Screenshot
Up to 4 interval messages can be generated and displayed in the software as visual message windows. This is useful for scheduled
system maintenance intervals. The following statuses can be queried:
Operating Hours [h]
Duration for which the eBOX has been switched on since the last reset
Delivery Time [h]
Duration of the actual eBOX wire feed process since the last reset
Cycles
Number of eBOX start/stop cycles completed since the last reset
Delivery amount [m]
Amount of eBOX wire used since the last reset
Default
A value of 0 – 1000 can be entered
Current
Shows the currently set values
Reset
Currently set values can be reset to zero
On/Off
Messages can be enabled or disabled
Edit