BAL.0193.0 • 2018-07-31
EN - 5
MT/AUT/AUT RAB
3 Product description
3 Product description
3.1 Technical Data
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert or modify the device to enhance its performance without authorisation.
• The device may only be used by qualified personnel (in Germany, see TRBS 1203).
Transport and storage
- 25 °C to + 55°C
Relative humidity
up to 90 % at 20 °C
Tab. 1
Ambient conditions during operation
Type of use
automatic
Type of voltage
DC
DC polarity of the electrodes
Usually positive
Shielding gas (DIN EN ISO 14175)
CO
2
and mixed gas M21
Wire types
commercially available round wires
Voltage rating
141 V peak value
Protection type of the machine side connections
(EN 60 529)
IP2X
Tab. 2
General torch data according to EN 60 974-7
Type
Type of
cooling
Load
Duty
cycle
Wire-
Gas
flow
Cooling data
dual
circiut
DC
Impulse
Supply
temp
flow
flow
pressure
CO
2
M21
M21
min.
min. max.
MT
A
A
A
%
mm
l/min
°C
l/min
bar bar
452 W
liquid
500 500
325
100
1,0 - 1,6
10 - 20
50
1,0
2
3,5
452 DW
liquid
450 450
300
100
1,0 - 1,6
10 - 20
50
1,0
2
3,5
645 W
liquid
650 600
450
100
1,0 - 1,6
10 - 20
50
1,0
2
3,5
Tab. 3
Product-specific torch data (EN 60 974-7) ABIMIG
®
MT