ADF 600S
6 Putting into operation
EN - 13
6.4 Protection levels
6.4.1 Adjusting the protection level for the welding process
1
Choose the protection level to be used that corresponds to your welding process.
1
Protection level 13
2
Grinding GRIND
3
Protection level 9
4
Controller
5
Protection level 10 (Fig. above)
6
Protection level 11
7
Protection level 12
Fig. 8
Protection levels
2
3
5
1
6
7
4
NOTICE
• Observe the information in the standard DIN EN 379.
Current intensity A
Procedure
1.5
6
10
15
30
40
60
70
100
125
150
175
200
225
250
300
350
400
450
500
600
Coated
electrode
8
9
10
11
12
13
14
MAG
8
9
10
11
12
13
14
TIG
8
9
10
11
12
13
MIG for
heavy
metals
9
10
11
12
13
14
MIG for
light
metals
10
11
12
13
14
Gouging
10
11
12
13
14
15
Plasma
cutting
9
10
11
12
13
Plasma
welding
4
5
6
7
8
9
10
11
12
Tab. 9
According to DIN EN 379