EN
-
18
10 Troubleshooting
ABICOOLER 1300
10 Troubleshooting
► Observe the documentation for the welding components.
► Note the warranty documentation provided.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Tab. 3
Troubleshooting
Fault
Cause
Troubleshooting
Device does not function
Power supply is interrupted.
► Switch on the power supply.
► Check the electrical system and contact
customer service as needed.
Motor/coolant pump is defective.
► Replace the motor/coolant pump.
► Contact the service team.
► Replace the fuse.
6.2 Initial commissioning on page EN
Too little or insufficient
coolant flow
No coolant in the coolant tank.
► Add coolant.
Coolant level is too low.
► Top up coolant.
Bottleneck or foreign object in the cooling circuit. ► Check the coolant hoses and connections.
► Flush the cooling circuit.
Coolant pump fuse is defective.
► Replace the fuse.
9.3 Replacing the fuse on page EN
Coolant pump is defective.
► Check the coolant circuit connections and
contact customer service as needed.
Coolant circuit is interrupted.
► Check the coolant hoses for damage and
replace them as needed.
Air in the coolant circuit.
► Bleed.
6.2.1 Bleed the device on page EN
Cooling capacity too low
Ventilator is defective.
► Contact the service team.
Coolant pump is defective.
► Contact the service team.
Cooling unit is dirty.
► Blow out the cooling unit with dry compressed
air.
Surrounding objects prevent the flow of air.
► Install the device so there is sufficient distance
from other objects.
High running noise level
Coolant level is too low.
► Top up coolant.
Coolant pump is defective.
► Contact the service team.
Leakage
The connections have leaks.
► Check for dirt and clean as needed.
Inner hoses have leaks.
► Contact the service team.
Coolant pump is defective.
► Contact the service team.
Coolant temperature is too high.
► Replace the hoses.
► Contact the service team.
► Clean the cooling unit.
► Check the fan for proper function.