ABEM Terraloc Pro 2
66
Figure 57 The View Options Dialog
Setting
Description
View mode -
The view mode determines how data is scaled for the display. The
following modes are available:
Name
Description
Enhanced
The data is not scaled, but the amplitudes are used
directly. It is, however, possible to attenuate the
displayed signals using the enhanced attenuation
parameter
Normalize
The max value in each trace is used to scale all samples
in the trace. See also global scaling
AGC
Uses the average amplitude calculated from a running
window (which length is specified by the AGC window
parameter). This means that each sample is scaled
according to the average signal level in the samples
vicinity
Hyperbolic Applies a hyperbolic scaling to the data. If the
logarithmic choice is selected, the function ArcSinH will
be used, otherwise the function TanH is used
Trace style
-
The following styles are available:
Name
Description
VAR+
This is a wiggle trace with the positive side filled-in
VAR-
This is a wiggle trace with the negative side filled-in
Wiggle
The trace is plotted as a wiggle
Dotted
Each sample value is plotted as a dot
Time
compression
-
Selects compression in time. This makes more of the record visible.
Available values are: