TH-308GB UHF SERVICE MANUAL
- 30 -
Adjustment
Required test Equipment
1
.
Stability power supply
1
.
The supply voltage can be changed between 5V and 18V, and the current is 3A or more.
2
.
The standard voltage is 7.5V
2
.
DC Ammeter
1
.
Class 1 ammeter (17ranges and other features).
2
.
The full scare can be set to either 300mA or 3A.
3
.
A cable of less internal loss must to be used.
3
.
Frequency counter (F. Counter)
1
.
Frequency of 1GHz or so can be measured
。
2
.
The sensitive can be changed to 500MHz or blow, and measurements are highly stable and
accurate .(about 0.2ppm)
。
4
.
Power Meter
1
.
Measurable frequency
:
Up to 500MHz
2
.
Impedance
:
50
Ω
, instability.
3
.
Measuring range
:
full scale of 10W or so.
4
.
A standard cable (5D2W 1m) must be used.
5
.
RF Voltmeter(RF V.M)
1
.
Frequency range
:
up to 500MHz or so.
6
.
Linear Detector
1
.
Frequency range
:
up to 500MHz or so.
2
.
Characteristics are flat, CN is 60dB or more.
7
.
Digital Voltmeter
1
.
Voltage range
:
FS=18V or so.
2
.
Input resistance: 1M
Ω
or more
8
.
Oscillograph
1
.
Measuring range
:
DC to 30MHZ.
2
.
Provide highly accurate measurements for5 to 25MHz.
9
.
AF Voltmeter (AF V.M)
1
.
Measuring range
:
50Hz to 1MHz
2
.
Maximum sensitivity
:
1mV or more.
10
.
Spectrum Analyzer
Summary of Contents for TH-308GB UHF
Page 29: ...TH 308GB UHF SERVICE MANUAL 28 Exploded View ...
Page 30: ...TH 308GB UHF SERVICE MANUAL 29 Packing View ...
Page 36: ...TH 308GB UHF SERVICE MANUAL 35 BPF Wave Figure 1 ...
Page 40: ...TH 308GB UHF SERVICE MANUAL 39 TH308GB Parts View Side A ...
Page 41: ...TH 308GB UHF SERVICE MANUAL 40 TH308GB Parts View Side B ...
Page 42: ...TH 308GB UHF SERVICE MANUAL 41 TH308GB PC Board View Side A ...
Page 43: ...TH 308GB UHF SERVICE MANUAL 42 TH308GB PC Board View Side B ...