AirCleaner
•
User Guide
75
4. Operations
Control Panel Menu Item Descriptions
This parameter has the following adjustable range:
•
= 0:01
Minimum value.
•
= 60:00
Maximum value (depending on memory installed, the
video format AirCleaner is currently programmed to
use, and the value of the “Total PGM Delay”
parameter; maximum may be shorter).
The
Video Reaction 1
parameter assigns the reaction time for the Screener 1
operator when the VIDEO Panic Button is depressed for Screener 1. This parameter
will “back-time” the button press to compensate for the time it takes the operator to
see a violation and then to react and press the VIDEO panic button.
The value of
Video Reaction 1
should be determined by testing the visual
reaction time of the operator. Refer to
for more info.
The
Video Reaction 1
parameter has a variable range that depends on the
video format of AirCleaner (set in the Options Menu), the current setting of the
Total PGM Delay
parameter, as well as the amount of delay memory fitted in
the machine at time of purchase. The delay ranges from 1 Frame up to 60 Seconds in
the case of SD 525 or 625 video format; or it can range from 1 Frame up to 6 Seconds
in the case of HD 1080i video with AirCleaner Model-1 (which is fitted with a
smaller amount of delay memory, compared to Model-2).
This parameter has the following adjustable range:
•
= 0:01
Minimum value.
•
= 60:00
Maximum value (depending on memory installed, the
video format AirCleaner is currently programmed to
use, and the value of the “Total PGM Delay”
parameter; maximum may be shorter).
The
Audio Reaction 1
parameter assigns the reaction time for the Screener 1
operator when the AUDIO Panic Button is depressed for Screener 1. This parameter
will “back-time” the button press to compensate for the time it takes the operator to
hear a violation and then to react and press the AUDIO panic button.
The value of
Audio Reaction 1
should be determined by testing the aural
reaction time of the operator. Refer to
for more info.
The
Audio Reaction 1
parameter has a variable range that depends on the
video format of AirCleaner (set in the Options Menu), the current setting of the
Total PGM Delay
parameter, as well as the amount of delay memory fitted in
the machine at time of purchase. The delay ranges from 1 Frame up to 60 Seconds in
the case of SD 525 or 625 video format; or it can range from 1 Frame up to 6 Seconds
in the case of HD 1080i video with AirCleaner Model-1 (which is fitted with a
smaller amount of delay memory, compared to Model-2).
Video Reaction 1
= 1:15
Audio Reaction 1
= 1:15
Summary of Contents for AirCleaner
Page 2: ...ii AirCleaner User Guide ...
Page 10: ...x AirCleaner User Guide Table of Contents ...
Page 54: ...44 AirCleaner User Guide 3 Updating Software Firmware Updating Software Firmware ...
Page 100: ...90 AirCleaner User Guide 4 Operations Control Panel Menu Item Descriptions ...
Page 106: ...96 AirCleaner User Guide Index ...