2. Installation
GPI, Ethernet & Power Connection
25. On the Windows PC, type the new IP Address of AirCleaner into the web
browser URL Address line, followed by ENTER to display the AirCleaner web
page.
This verifies you’ve properly updated the AirCleaner IP Address:
Please refer to
“Updating Software & Firmware” on page 27
AirCleaner’s software and/or firmware.
AC Power Input
AirCleaner features up to two AC power input receptacles, to handle the redundant
power supply option. If by chance AirCleaner is not configured with the redundant
supply option, the AC receptacle nearest the outside edge of the chassis (the RIGHT
plug, when viewing the chassis from the rear) will be fitted, while the other will be
covered up with a metal cover plate.
Each power supply is auto-sensing and runs from a minimum of 100VAC/3.0A to a
maximum of 240VAC/1.5A, from 50Hz to 60Hz. When two power supplies are
installed, the power load is shared between the two supplies; if one supply were to
completely fail, the other power supply will automatically take over the full power
load, and is capable of fully running the AirCleaner.