![ABB XFC G5 User Manual Download Page 24](http://html.mh-extra.com/html/abb/xfc-g5/xfc-g5_user-manual_3228024.webp)
24
| XSERIES G5 | 2106026MNAA
1.5.1
Battery and charger power configurations
The battery mode consists of the 12-volt battery and a charger. The configuration depends on the
type of charger used: a solar panel charger or a power supply used as charging source.
IMPORTANT NOTE:
Battery sizes vary between 8 and 26 ampere hours, depending upon
installation requirements. The battery can be model-option specific, including larger battery
sizes.
Table 1-9: Battery power mode connections
Port
Connector to use
Connection type
BATT
XFC: J1
XRC: J16
Connect to the 12-volt SLA Battery
CHRG
XFC: J5
XRC: J17
Connect to:
Solar panel
or
DC power supply charging source
1.5.1.1
12-volt battery with solar panel configuration
This battery-powered configuration includes a 12-volt sealed lead acid (SLA) and a solar panel as the
charger. Solar panel chargers are available in 10, 20, and 30-watt kits.
The battery is installed inside the enclosure. The solar panel mounts on the enclosure mounting pipe
or on the roof of a nearby structure.
1.5.1.2
12-volt battery with power supply configuration
This battery-powered configuration includes a 12-volt sealed lead acid (SLA) and a DC power supply
as the charging source. The power supply must be set to 14.5 to 15.5 Vdc and must be rated for 2A
minimum.
1.5.2
External power supply configuration
The external power supply configuration includes a power supply as the power source to the device.
The voltage range must be from 12Vdc to 14Vdc.
IMPORTANT NOTE:
Power supplies can be installed outside or inside of enclosures. Power
supplies that are installed inside must be ABB-approved and must fit in the selected
enclosure. Verify the options available for your enclosure size and requirements.
Table 1-10: External power supply mode connection
Port
Connector to use
Connection type
BATT
XFC: J1
XRC: J16
Connect to external power supply
CHRG
NOT USED
NOT USED
The RTD is a separate sensor which provides the temperature inputs to the XFC
G5
IXMV or external
measurement transmitters. This is a 100
Ω
platinum RTD designed to measure the real-time flowing
temperature of the process gas. The XFC
G5
electronic board supports a dedicated input terminal for
connection with an RTD.
IMPORTANT NOTE:
The XRC
G5
electronic board does not have an integrated multivariable
measurement system or a dedicated RTD input port. RTDs are used in conjunction with
external measurement transmitters which connect to other communication interfaces on the
XRC
G5
. Support of additional tubes on the XFC
G5
also requires external transmitters and
additional RTDs.
Summary of Contents for XFC G5