- 22 -
000318CG
2 - Characteristics
T
ightening torques
To maintain the IP65 protection of the system and for optimal installa-
tion, the following tightening torques must be used:
AC cable gland
15
M32
8.0 Nm
Service cable glands
16
M25
7.5 Nm
Service cable glands
16
M20
7.0 Nm
DC cable glands
18
M25 (only standard versions)
7.5 Nm
Front cover
04
2.4 Nm
Input terminal block
23
- 16 mm
2
Max
(standard versions)
1.5 Nm
AC output terminal block
31
- 10 mm
2
Max
1.5 Nm
Signal terminal block
29
- 1.5 mm
2
Max
0.25 Nm
MC4 or Weidmuller quick fit connectors
2.5 Nm
O
verall dimensions
The overall dimensions are expressed in millimetres and inches and in-
clude the wall installation bracket
220
mm
8.7
”
641 mm - 25.2”
429 mm - 16.9”
237
mm
9.3
”
855 mm - 33.7”
429 mm - 16.9”
TRIO
POWER ALARM
GFI
ESC
UP
DOWN ENTER
POWER ALARM
GFI
ESC
UP DOWN
ENTER
TRIO