Operation Manual / 4 Product description / TPS44-H.. - TPS52-H..
2
Removing and Installing
Page 13 / 99
© Copyright 2016 ABB. All rights reserved.
HZTL4037_EN
Revision A
August 2016
Figure 5: Removing the turbocharger
1. Treat the threads of studs and nuts with penetrating oil and allow to work in.
2. Loosen and remove nuts.
3. If present: Disconnect the plug to the speed sensor (86505) and secure the rolled-up cable
on the turbocharger. This protects the plug from being crushed.
4. Install the swivel lifting eye (S) and attach the lifting gear to it.
5. Lift the turbocharger away from the support vertically.
6. Cover the connections.
Version with water cooling
CAUTION
Freezing of the cooling water in the bearing casing
If cooling water freezes in the bearing casing, this can lead to severe dam-
age.
For transport and storage of the turbocharger, drain the cooling water
from the bearing casing via one of the two bottom openings of the water
connections.